OCR status: ok · source: pdftotext

Z ■< Z ■<

o o g co AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY I o “0 o PROJECT: NYCDEP, 101 Maiden Lane c o CLIENT: Warren & Panzer Engineers, P.C. CT o Ca5 ATHENICA LABORATORY ID #: T02-09-032 DATE OF REPORT: 09/10/02 o' o> ENVIRONMENTAL SERVICES INC. ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 09/10/02 "0 Oi o o TeL (71») 704-7«0 FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 Fax. (718) 784-W85 AVERAGE G.O. AREA 0.013771 9L O o o c LABORATORY RESULTS 3 o 3

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cin’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (rnm^) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./inm^) 0.5<S<5|rni S>5.0|xm 01 T02-09- East Roof Top 1800 4 0.0551 0.0039 0.0039 uciy 0.0039 <0.0039 Chrys. NA 032-2229 02 T02-09- West Roof Top 1800 4 0.0551 SAMPLE OVERLOADED WITH PARTICULATE MATERIAL RENDERING 032-2230 IT UNACCEPTABLE FOR ANALYSIS 03 T02-09- North East 1800 4 0.0551 0.0039 <0.0039 <18.15 NA NA NA NA 032-2231 Roof Top 04 T02-09- North West 1800 4 0.0551 0.0039 0.0039 18.15 <0.0039 0.0039 Chrys. NA 032-2232 Roof Top 05 T02-09- Adjacent Roof 1800 4 0.0551 0.0039 <0.0039 <18.15 NA NA NA NA 032-2233 Top(Electric room)

^^2 ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. K If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is I supplied solely for the convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced O except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc with respect to the .services charged, shall in no event exceed the amount of the invoice. o I o o co o o Ui co o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346501Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →