Airborne asbestos TEM analysis, NYC DEP project

Machine-extracted title · confidence 41%

TEM analysis results for airborne asbestos; client Warren & [name], P.C.; NYC DEP project at Fulton Street.

NYC-WTC_000345045
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 111 Fulton Street LABORATORY ID #: T02-07-019 DATE OF REPORT: 07/25/02 ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 07/25/02 ENVIRONMENTAL SERVICES INC. FILTER TYPE: M.C.E. EFFECTIVE FILTER AREA (mm^): 385 TN. (71S) 784-7400 AVERAGE G.O. AREA (mm^); 0.008643 Fw. (718) 784-4O8S

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<Spm S>5.0nm 3 T02-07- Decon 1800 5 0.0432 0.0049 0.0049 23.14 <0.0049 0.0049 Chrys. NA 019-1039 4 T02-07- Exit from roof 1800 5 0.0432 0.0049 0.0049 23.14 <0.0049 0.0049 Chrys. NA 019-1040 5 T02-07- East side of roof 1800 5 0.0432 0.0049 <0.0049 <23.14 NA NA NA NA 019-1041 6 T02-07- West side of roof 1800 5 0.0432 0.0049 <0.0049 <23.14 NA NA NA NA 019-1042 7 T02-07- North side of 1800 5 0.0432 0.0049 0.0049 <23.14 NA NA NA NA 019-1043 roof

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. 1^ Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time ftame for atrue duplicate analysis. I If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is to supplied solely for t6e convenience of the client. S rhe report relates only to items tested This report must not be used to claim product endorsement by NVLAP or any othci agency of the U.S. Government. Test reports may not be reproduced o except in full and with prior approval of AES Inc. o fhc liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o I o o to CD to

NYC-WTC_000345045

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000345045Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →