NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Airborne asbestos analysis, TEM, Fulton Street

Machine-extracted title · confidence 34%

TEM asbestos analysis report for NYC DEP project at 70 Fulton Street; dated 2002.

NYC-WTC_000344915
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z Z o o g o AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY I o “□ o CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 70 Fulton Street c o CT Ca5 ATHFNIPA laboratory ID#: T02-09-096 DATE OF REPORT: 09/27/02 o' A I nCIMIVK ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 09/27/02 "0 CD ENVIRONMENTAL SERVICES INC. pjLygjj l YPE: M.C.E. o EFFECTIVE FILTER AREA (mm^): 385 cn 03 ?'■ AVERAGE G.O. AREA (mn?): 0.013838 rax. (718) 78'N^aob O o LABORATORY RESULTS o c 3 o CLIENT # LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. 3 # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) O.S<S<5|am S>5.0|um 001 T02-09- East roof 1620 4 0.0554 0.0043 <0.0043 <18.07 NA N^ NA NA 096-2561 002 T02-09- East roof 1620 4 0.0554 0.0043 <0.0043 <18.07 NA NA NA NA 096-2562 003 T02-09- Inside building 1620 4 0.0554 0.0043 <0.0043 <18.07 NA NA NA NA 096-2563 004 T02-09- West roof 1620 4 0.0554 0.0043 <0.0043 <18.07 NA NA NA NA 096-2564 005 T02-09- West roof 1620 4 0.0554 0.0043 <0.0043 <18.07 NA NA NA NA 096-2565

/3

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. o Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis If AES Inc,, did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is I supplied solely for the convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S Government. Test reports may not be reproduced except in full and with prior approval of AES Inc. rhe liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. O o I o o

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000344915Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →