Z Z o o i 1^ AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY

CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 52 William Street co

o "0 o LABORATORY ID #: T02 11 099 DATE OF REPORT: 11/22/02 c o CT ro co ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 11/22/02 o' Ca3 Ef’fYlRONMENTAL SERVICES INC. FILTER TYPE: M C E EFFECTIVE FILTER AREA 385 "0 Ca5 o Td. (718) 784-7490 AVERAGE G.O. AREA (mm^): 0.013433 ro 9L Fax. (718) 784-4085 LABORATORY RESULTS O o o c CLIENT # LAB. ID # LOCATION YOLLME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. 3 ASBESTOS CONC. CONC. TYPE ASBEST Q (It) ANAL AN ALY SENSITIV. ASBESTOS 3 YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mra’) (strncjcm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) O.S<S<5)im S>5.0|rm 01 T02-11- Exit to roof 1560 4 0.0537 0.0046 0.0138 ssysT” 0.0092 0.0046 Chrys. NA 099-4206 02 T02-11- 2'“ exit to roof 1560 4 0.0537 0.0046 <0.0046 <18.61 NA NA NA NA 099-4207 03 T02-11- IWA right side of 1585 4 0.0537 0.0045 <0.0045 <18.61 NA NA NA NA 099-4208 WA 04 T02-11- IWA middle of WA 1585 4 0.0537 0.0045 <0.0045 <18.61 NA NA NA NA 099-4209 05 T02-11- IWA left side of 1585 4 0.0537 0.0045 <0.0045 <18.61 NA NA NA NA 099-4210 WA

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. H Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client. The report relates only lo items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced o except in full and with prior approval of AES Inc. O The liability of ^Vthenica Environmental Services Inc. wnth respect to the services charged, shall in no event exceed the amount of the invoice. O I o o

CD O CO

O

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000283312Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →