Airborne asbestos analysis by TEM, NYC DEP

Machine-extracted title · confidence 43%

Airborne asbestos TEM analysis for NYC DEP; lab ID T02-08-120; date 08/24/02.

NYC-WTC_000344840
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 40 ExchangePl, NY, NY ATHENICA LABORATORY ID #:T02-08-120 DATE OF REPORT: 08/24/02 CMOIOOKUICKITA. iMT ANALYT. METHODOLOGY: AHERA CNVivVwIMRnCN I AL dCKVIvCw IMw ■ DATE OF ANALYSIS: 08/24/02 TeL (718) 784-7«0 FILTER TYPE: MCE EFFECTIVE FILTER AREA (mm^): 385 Fax. (718) 7BM085 AVERAGE G.O. AREA (mm’): 0.012422

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIRCONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./inin’) 0.5<S<5(Tin S>5.0|tm 01 IWA T02-08- On roof, Center 1800 4 0.0497 0.0043 <0.0043 <20.13 NA NA” NA NA 120-1822 of work area 02 IWA TO2-O8- On roof, South 1800 4 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 120-1823 section of W.A. 03 IWA T02-08- On roof. North 1800 4 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 120-1824 section of W.A. 04 IWA T02-08- On roof. South­ 1800 4 0.0497 0.0043 <0.0043 <20.13 NA NA NA NA 120-1825 east section of W.A 05 IWA T02-08- On roof, 2ft of 1800 4 0.0497 0.0043 0.0043 20.13 0.0043 <0.0043 Chrys. NA 120-1826 door access to the roof.

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o

K Athenica Environmental Services Inc, (AES), is responsible only for information pertaining to samples taken by its employees. I Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is S supplied solely for the convenience of the client. o The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced o except in full and with prior approval of AES Inc o I The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o

kO

CT)

NYC-WTC_000344840

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000344840Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →