Air monitoring log sheet, 228 E 45th St, 2002

Machine-extracted title · confidence 42%

Air monitoring log/COC for PCM AHERA sampling at 228 East 45th Street.

NYC-WTC_000345162–000345169
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY

CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYCDEP, 141 Fulton Sfreet. NY ATHENICA LABORATORY ID #; T02-10-005 DATE OF REPORT: 10/01/02 ENVIRONMENTAL SERVICES ir^NALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 10/01/02 Tel. (718) 784-7490 FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm’): 385 Fax. (718) 784 4085 AVERAGE G.O. AREA (mm’): 0.013838

LABORATORY RESULTS

CLIENT # LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (stnic./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5p.in S>5.0pm 1 T02-1O- IWA on roof. Center 1800 4 0.0554 0.0039 <0.0039 <18.07 NA N^ NA NA 005-2705 of work area 2 T02-10- IWA on roof. North 1800 4 0.0554 0.0039 <0.0039 <18.07 NA NA NA NA 005-2706 section of WA 3 T02-10- IWA on roof.4ft of 1800 4 0.0554 0.0039 <0.0039 <18.07 NA NA NA NA 005-2707 door entrance of roof 4 T02-10- OWA on roof. 1800 4 0.0554 0.0039 0.0077 36.13 <0.0039 0.0077 Chrys. NA 005-2708 Inside clean room of Decon 5 T02-10- OWA 3ft of door 1800 4 0.0554 0.0039 <0.0039 <18.07 NA NA NA NA 005-2709 entrance on stairwell leading to roof

J 31

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

o LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 K I Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. S If AES Inc , did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these cirCLimstances, the air concentration data is o supplied solely for the convenience of the client. o The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced o I except in full and with prior approval of AES Inc. o The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice.

o co co wo cn

NYC-WTC_000345164

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000345164Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →