NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 29 Broadway Street LABORATORY ID #: T02-07-021 DATE OF REPORT: 07/25/02 ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS; 07/25/02 EN\ARONMENTAL SERVICES INC. FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 Tel. (7X8) 784-7490 AVERAGE G.O. AREA (mm^): 0.008643 Fax. (718) 784-4085

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL AN ALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm^) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm^) (struc./cin/) CONC. STRUCT. STRUCT. SPECIFY (str./min’) 0.5<S<5p.ni S>5.(lnin 01 T02-07- Near decon, 6**" 1350 7 0.0605 0.0047 <0.0047 <16.53 NA NA NA NA 021-1049 floor 02 T02-07- Rear part of 1350 7 0.0605 0,0047 <0.0047 <16.53 NA NA NA NA 021-1050 building 6* floor 03 T02-07- In the middle of 1350 7 0,0605 0,0047 <0.0047 <16.53 NA NA NA NA 021-1051 the roof 04 T02-07- Rear of roof 1350 7 0.0605 0.0047 <0.0047 <16.53 NA NA NA NA 021-1052 05 T02-07- Back of roof 1350 7 0.0605 0.0047 <0.0047 <16.53 NA NA NA NA 021-1053

ANALYST LABORATORY DIRECTOR E. Dimitrakas Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955 o Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. H Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for t6e convenience of the client. The report relates only to items tested. This report must not be used to claim product endorsement by NVI AP nr any other agency of the U.S. Government. Test reports may not be reproduced O except in full and with prior approval of AES Inc. O The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. O Io o

co o

NYC-WTC_000343856

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000343856Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →