Hillmann Environmental Group, LLC

Additional air quality testing was performed on various floors on October 13, 2001. PCM clearance air sample results were obtained, with no sample concentration exceeding 0.01 f/cc.

Specific air sample locations and results can be seen in the Air Sample Result Listings in table 4.1.

4.3 Balk Sample Analysis

Bulk samples were collected and analyzed prior to and at the commencement of the cleanup of various areas of the hotel. Sampling was conducted by a qualified industrial hygienist.

Bulk debris samples were collected from the rooftops on various levels of the facility. Each of these samples was identified to contain asbestos in concentrations less than 1% by PLM analysis. Sampling was also conducted on the windowsills of rooms on various floors throughout the building. One sample on the windowsill of room 3015 on the 30* floor was found to contain asbestos in concentrations less than 1% by PLM analysis. No asbestos was detected in the other samples taken on floors 1, 4, 5, 7, 10, 15, 20 and 25.

Numerous bulk samples were also collected from the first floor flower and gift shops. Each of these samples was found to contain less than 1% asbestos by PLM analysis.

4.4 Summary of Abatement Activities

Prior to the commencement of clean-up activities the asbestos abatement contractor erected critical barriers to stop the flow of air to and from Roy’s Restaurant, the adjoining kitchen and adjacent lobby. Air filtration devices were set up within this containment area to actively filter the air within the work area. Once these engineering controls were established clean up of the debris began.

All non-cloth surfaces were wet wiped with clean rags prior to being vacuumed with a HEPA equipped vacuum. Walls, tables and floors are examples of surfaces cleaned in this fashion. Cloth surfaces were cleaned using the HEPA equipped vacuum. These surfaces include carpeted floors and upholstered chairs, which were to be salvaged. When the clean up was complete, die industrial hygienist conducted a visual inspection. Air samples were collected, and once clearance levels were obtained the engineering controls and barriers were removed.

Marriott World Financial Center/Project Number Yl-3508 Page 5

CITY_DEP_WORBY_CANNATA_SUBP_000006728

NYC-WTC_000342988

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342988Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →