Advanced Environmental air monitoring report

Machine-extracted title · confidence 40%

Limited air monitoring report for 79 [name] basement therapy room with asbestos data.

NYC-WTC_000342821–000342822
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

33/06/2002 08:03 2125450757 ADVANCED ENVIRONMENT PAGE 33

Recovery Physical Therapy Air Monitoring for Asbestos, Respirable Dust, and Priority Pollutant Metals Basement Therapy Room, 79 Maiden Lane, New York, NY ^4ra<Ke4 Bnvironmetttel Carp.

In accordance with the sampling protocol a Gillian 10-mm nylon cyclone was utilized during sample collection. The concept of the cyclone is to separate respirable dust from particulate matter of 10 micron pore size or greater. With the air flow rate calibrated to 1,7 LPM, the cyclone inlet draws in the air and creates a spiral action or vortex, which separates the larger particles from the lighter ones. The cyclone’s grit pot accepts the heavier particles while the lighter particles (less than 10 microns) are drawn up and impacted onto the filter cassette.

The sample data is presented as a ration of particulates measured (by weight) per volume of air collected. The sample results indicated a Total Respirable Dust (or PNOC) concentration of 0.0173 mg/m’' which is well below the OSHA Permissible Exposure Limit (PEL) of 5 mg/m\ These results can be found in Appendix B.

Metals

Sampling was performed to determine levels of priority pollutant metals in the ambient air. One (1) sample was collected and analyzed according to EPA1987 Methods 200.7 and 245.1 for priority pollutant metals analysis. The sample was collected on a 0.8-pm pore size mixed cellulose ester filter using a 37 millimeter cassette. A low flow volume personal air pump weas used to draw air through the filter media. Flow rates were measured with a Mini Buck calibrator model M-30, before and after sampling to ensure an accurate volumetric reading. The sample was collected closed face in accordance with the sampling protocol.

The priority pollutant metals tested include Antimony, Arsenic, Beryllium, Cadmium, Chromium, Copper, Lead, Mercury, Nickel, Selenium, Silver, Thallium, and Zinc. The sample results detected no airborne concentrations of priority pollutant metals with the exception of chromium. The sample result indicated a total chromium concentration of 0.619 pg/m’’ which is well below the OSHA Permissible Exposure Limit (PEL) of 500 pg water soluble chromium (HI) compounds per cubic meter of workplace air (500 pg/m^), 1,000 |ig/m^ for metallic chromium (0) and insoluble chromium compounds, and 52 Ug/m’ for chromium (VI) compounds for 8-hour work shifts and 40-hour work weeks.

These results can be found in Appendix C-

Summary

In conclusion, sample data obtained for asbestos, respirable fraction dusts, and priority pollutant metals, arc well below applicable exposure standards for these substances. If you have any questions or need further clarification on air sampling methodology, please call me.

Sincerely,

Edward Namath Principal

1213,001 "cpqserver I 'd»u'4cc'£llMil3tt<Ki>vey phyiicalWS maiden is snip rpLdoe

347 Fifth Avenue, Suite 404. New York, New York 10016 Phone 212-545-1855 Fax 212-545-0757

CITY_21MC100_003008473

NYC-WTC_000342822

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342822Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Air monitoring letter, 79 [name], Feb 2002

NYC-WTC_000205664

Letter from Advanced Environmental Corp. reporting limited air monitoring for asbestos and dust at a therapy room on Feb 12, 2002.

Similar indexed content

NYC-WTC_000342619

Narrative on bulk sampling, visual assessments, air monitoring; TEM samples collected.

Similar indexed content

Compare copies and versions →