NYC 9/11 Public Portal Document
03/06/2002 08:03 2125450757 ADVANCED ENVIRONMENT PAGE 02
dvanced Environmental Corp.
February 21,2002
Mr. Robert Spatz
Recovery Physical Therapy
79 Maiden Lane
New York, NY 10038
Re: Air Monitoring, Basement Therapy Room, 79 Maiden Lane, New York, NY
Dear Mr. Spatz;
On February 12, 2002, Advanced Environmental Corp, performed limited air monitoring at the above
location. Samples were collected to document the asbMtos, respirable dust, and priority pollutant metal
concentrations of the ambient air from the basement therapy room at 79 Maiden Lane, New York, NY.
Please be advised that this information is not intended to comply with OHSA permissible exposure
monitoring requirements or requirements for clean air following asbestos abatement work. We reference
the OSHA standards and abatement release criteria to merely give information for comparative reasons.
Asbestos
One (1) sample was collected and analyzed using the Transmission Electron Microscopy (TEM) method
according to the EPA AHERA protocol. TEM with energy dispersive X-ray analysis is an analytical
method that enables a fibers chemical composition to be identified, in this case asbestos. This fiber
specific protocol is generally utilized to determine clean air following a "large" abatement project. TEM
sample analysis detects filter loads (the number of structures detected per square millimeter of collection
media surface) which, if less than or equal to EPA-AHERA release criteria of 70 structures per square
millimeter (s/mm’), determine whether or not the area is safe for re-occupancy.
The sample was collected on a 0-4-um pore size, 25 mtn mixed cellulose ester filter/support pad cassette,
with a 10 mm electrostatic cowl. High volume air pumps were used to draw air through the filter media.
Flow rates were measured with a calibrated rotameter, before and after sampling to ensure an accurate
volumetric reading.
The TEM sample was collected from basement therapy room. The sample results can be found in
Appendix A. Listed is the sample identification number, area analyzed, sample volume, structure counts,
analytical sensitivity, and the concentration of asbestos. As a review of Appendix A shows, no asbestos
structures were detected on any samples collected.
Respirable Dust (Particulates {insolnable} Not Otherwise Classified [PNOCs]
One Respirable Dust air sample was collected and analyzed according to the National Institute of
Occupational Safety and Health (NIOSH) 500/600 method. The sample was collected on a 5-gm pore size
pre-weighted PVC membrane filter using a 37 millimeter cassette. A low flow volume personal air pump
was used to draw air through the filter media. Flow rates were measured with a Mini Buck calibrator
model M-30, before and after sampling to ensure an accurate volumetric reading.
347 Fifth Avenue, Suite 404, New York. New York 10016 Phone 212-545-1855 Fax 212-545-0757
CITY_21MC1OO_OO3OO8472
NYC-WTC_000342821
OCR can misread numbers and units. Confirm readings against the page image before using them.