NYC-WTC_000390877
Chain-of-custody and methodology description for asbestos bulk material analyses using PLM-DS.
2 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗Chain-of-custody for bulk asbestos samples and PLM-DS methodology, Dec 2001.
NYC-WTC_000342699OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document ®021 ''2/2?/20';2 02:'?' FAX ic‘4«-rt JLC ENVITONMEMTPL 10,379 P.3
Mazat Group LLC (100 John Street) page 2 JLC Project #01-2094001 Bulk BMHcBno Materiala Artaivaia and Procedure
Introduction Pdahzed light microscopy with dispersion staining (PLM-DS) is the moat efficient method for detecting asbestos in bulk samples, it is this method that the JIX lab uses during bulk building nwterial analyses.
Methodology A Chain of custody is kept tor each sample to ensure proper handling and delivery to the JLC lab prior to analysis. To avoid any possible aortamlnation, alt sample and slide preparation is carried out in a ventilated. HEPA-tIfter hood with continuous airflow. Sample analysis Ie pertormed using PLM-DS in accordance with the USEPA. ‘Method tor the Determinetion of Asbestos in Bulk Building Materials,’ EPA 600 R-93116, July 1993, and NYDOH-5UAP certification manual, "Polarized Light Microscope Methods tor Identifying and Quantitating Asbestos in Bulk Samplae," ELAP 198,1, October 1993.
Analytical Procedures All samples are subject to preliminary visual steraomicroscapic examination. Observation of homogenaity, fiber iaenfification, and semi-Quantitation of constituents can ba made at this point Samples lacking uniformity of oomposition and/or distribution of component materials then undergo homogenizaticn. Some non-fn'aWe organicaity bound (NOB) samples such as floor tiles and roofing material# may require adcktionsi steps to dislodge problem matiiees (i,e. ashing, extractions, and!EM),
Identification of suspectfibers is made by PIM analysis ofsubsamples. A microscope equipped with dual polariaing filters enables us to observe specific optical characteristics of each sample* Positive identification of asbestos requires determinstion o'the following optical properties; morphology, oolcrand pleochroism, refractive indioBS, birefringence, extinction characteristics, end signa of dongation.
, Asbestos quantitation ia perfonned by point-counting procedira, a standard technique in petrography for detamining the relative areas occupied by separata minerals In rock. An ocular retide auperimposss a point or pointe over the microecopa's field of view. The number of points positioned directly above each kind or particle or Aber Is recorded. A total of 400 points must be counted over at least eight different representative subsarr plea to complete analysis.
Poiarizad Light Microscopy JLC uses an Oiympue 0HT-P ^olanang MicroscopB complete with polarizer, analyzer, port for wave retardation ptata, 380 degree graduated rotatino stage, substage condenser, lamp and lamp iris, eyepiece reticle, and 2S point Chalkley Point Array. Plane poiarizad iiglit allows tor the daterminaton of refraction indices relative to specific crystallographic orientations. Mor^ology end color can also be observed under plane polarized light Observation of particles or fibers while oriented Cutwsen polarizing flRBrs whose privileged vibration directions are perpendfculsr allows tor determination of isotropism smstropism, extinction charaeteTisitas of anisotropic partictss. and calculation of btreWngencs. a retardation plate may be placed tn the polarized light path tor venflcetion of signs of alongetion.
Analytical Resultc The "Summary of Analytical Results" represents the results of analysis. Positive results mean the sample is asbestos or contains more then ope percent asbestos by weight The results are generally sufficient for {dentWcation and quantRadon of major eoncentrallena or asbestos, However, it may be found that additiQnal techniques may be necessary. Reue be aware that PLM is not oonsistenly reliable in detecting estsastos in floor coverings and similar NOB materials. Before the material can M considered or treated a* non-aefcastos containing, confirmation must oa made by quantitative Transmission aactron Microscopy PTSM),
2^1
CITY_DEP_WORBY_CANNATA_SUBP_000006551
NYC-WTC_000342699
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000390877
Chain-of-custody and methodology description for asbestos bulk material analyses using PLM-DS.
2 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390908
Chain-of-custody for bulk building material sampling at site.
2 shared non-person entities · 1 shared topics · similarity 0.978
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000365851
Chain-of-custody narrative for bulk material samples analyzed by JLC for asbestos.
2 shared non-person entities · 1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367020
Analytical results of building materials inspection across multiple Rector/ Battery Place addresses.
2 shared non-person entities · 1 shared topics · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306165
Faxed chain detailing friable/non-friable asbestos and bulk material sample results.
2 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367027
Summary of analytical results for asbestos analysis on 99 Battery Place samples.
2 shared non-person entities · 1 shared topics · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367031
Summary of PLM asbestos analysis for samples from 99 Battery Place.
2 shared non-person entities · 1 shared topics · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000277312
Chain-of-custody for bulk building material samples and PLM-DS methodology description.
2 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357468
Chain-of-custody cover for building material inspection samples at 3 World Financial Center, Floors 3-26.
2 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321933
JLC materials inspection with friable/non-friable asbestos assessment and protocol references.
3 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000268945
Analytical results for bulk asbestos samples from 3 World Financial Center floors 3-26.
2 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000104616
Fax cover sheet dated March 11, 2002 transmitting documents regarding DEP regulatory compliance at 110 Fulton Street.
2 shared non-person entities · 1 shared topics · similarity 0.923
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000277312
Chain-of-custody for bulk building material samples and PLM-DS methodology description.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418335
Chain-of-custody for air monitoring samples collected after 2001 event at 21 West Street; references lab results and contractor contacts.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390877
Chain-of-custody and methodology description for asbestos bulk material analyses using PLM-DS.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321933
JLC materials inspection with friable/non-friable asbestos assessment and protocol references.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390908
Chain-of-custody for bulk building material sampling at site.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000306165
Faxed chain detailing friable/non-friable asbestos and bulk material sample results.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000277312
Chain-of-custody for bulk building material samples and PLM-DS methodology description.
Similar indexed content
NYC-WTC_000390877
Chain-of-custody and methodology description for asbestos bulk material analyses using PLM-DS.
Similar indexed content
NYC-WTC_000390908
Chain-of-custody for bulk building material sampling at site.
Similar indexed content
NYC-WTC_000365851
Chain-of-custody narrative for bulk material samples analyzed by JLC for asbestos.
Similar indexed content
NYC-WTC_000367020
Analytical results of building materials inspection across multiple Rector/ Battery Place addresses.
Similar indexed content