Concrete field inspection, WTC paving, June 2002

Machine-extracted title · confidence 28%

Field inspection report for concrete at WTC paving project (June 2002).

NYC-WTC_000342401
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MUNICIPAL TESTING LABORATORY, INC. 102 NEW SOUTH ROAD, HICKSVILLE, NEW YORK 11801, 516-938-7120, 516 938-5107 FAX CONCRETE REPORT LI RO Group/NYC DDC Attn: Mike Bailey Report Date: 6/4/02 '-.Yddress: Six Aerial Way Report Number: D0964 Lab#: 1293 Syosset, NY 11791 Date Cast: 512102 Project: WTC Paving Project Contractor: Tully/Grace Concrete Plant: N/A Strength PSI: 3500 Yards Placed: 40 FIELD INSPECTION REPORT

Pour Location for Set # 1: 25' North of curb line intersection w/Hubert St. & Greenwich St. (East side) by ECS head.

Pour Location for Set # 2: Pour Location for Set # 3: Tests made in accordance with ASTM: Yes Not Known Field Inspector Is) : Client

ASTM C 39 COMPRESSIVE STRENGTH TESTS AREA: 28.27 Cylinder Dia: 6‘ Cylinder Date Date Slump Air Unit Wt. Temp F. Truck Tested Load Strength Required Type ID « Cast Tested C143 :173, C23 C138 C1064 No. Age KN PSI Strength Frac Cylinder Set # 1 1962A 5/2/02 5/9/02 4.0 7 510.2 4,060 3,500 A 1962B 5/2/02 5/30/02 4.0 28 613.6 4,880 3,500 A 1962C 5/2/02 5/30/02 4.0 28 603.8 4,800 3,500 A

Cylinder Set # 2

Cylinder Set # 3

t Remarks:

Reviewed By. Laboratory Director Richard Kasparian, P.E are conducted In accordance win ASTM 019 or AASHTO T-22, By tecftnicians certified by ACI. Municipal Teatins «inspected by the Cement and Concrete Relerence Laboratory ol The National Institute ol

■ ards and Teclinology and is Accredited by; AASHTO and is Licensed by: New Yorii City {at9) and by The State ol Florida, this report relates only to the Item or exact locadon/item testad.

nol to me enure construction. it can only M reproouceo in tug. aiM only win MunlcHial Testins UaOoratory. Inc. wrttten permission. Our Batilllly Is strictly lirnilsa to ne lee palO. 02.224243

CITY_21MC100_004031030

NYC-WTC_000342401

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342401Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →