Air sample results, silica and CO observations, WTC

Machine-extracted title · confidence 35%

Report noting silica exposures and carbon monoxide trends in WTC recovery area with protection guidance.

NYC-WTC_000342098
Page image
Scanned page image, NYC-WTC_000342098
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

liberty

Industrial Hygiene Air Sample Results

Silica Exposures During Concrete Work

Both OSHA and we have found silica exposures in excess of the exposure limit during working with and on concrete. Personnel drilling, breaking, and mixing concrete or grout should wear respiratory protection during these jobs.

Noise

Noise is becoming a more important exposure as the job progresses to lower levels. Workers should wear ear protection when using chain saws, pneumatic hammers, and other tools that can produce hearing zone noise levels in excess of 90 dBA. Workers should be in a hearing conservation program if 8 hour average exposure exceed 85 dBA.

Carbon Monoxide

Carbon monoxide (CO) exposures may increase because more work is being done below grade level. Although time-weighted average exposures are below the OSHA PEL of 50 ppm, we have seen short-lived peak levels in excess of the ceiling level guideline of 200 ppm. This is not a legally enforceable exposure limit, but it serves as an indication that high levels of CO can occur under certain conditions.

If ventilation is reasonably good, it is not likely that concentrations will be excessive. However, be aware of any internal combustion equipment being used in spaces with restricted ventilation could trap exhaust gases in the space.

Please remember that the negative pressure respirators being used on site are not approved for carbon monoxide. Therefore, it is very important that excessive exposure to carbon monoxide be avoided.

If you have questions concerning the enclosed sample results or any questions concerning occupational disease exposures or controls, feel free to contact the Liberty Mutual Industrial Hygienist on duty @917- 566-2576.

Mike Ramsey, CSP, CIH Senior Industrial Hygienist Liberty Mutual Insurance Group

December 15,2001

CITY_21MC1OO_OO2989134

NYC-WTC_000342098

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000342098Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000342088

Industrial hygiene air samples with sulfuric acid exposure and respiratory-protection notes.

Similar indexed content

Compare copies and versions →