NYC-WTC_000357887
Air sample results memorandum; notes on area and personal samples.
6 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗Weekly summary noting PEL/TLV percentages and not-quantifiable analyses for the period.
NYC-WTC_000342107OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
liberty Mutual. Industrial Hygiene Air Sample Results Contractor: _____________________ Dates Covered: Z//2.7 TV /2-/i ~ Enclosed are the results fi-om industrial hygiene air samples recently collected in your area of the WTC recovery operation. These samples were collected by ATC Associates, Inc.
Samples marked as “personal” samples were collected by having the worker wear the sampling device. Results fi-om personal samples are representative of the time-weighted average exposure experienced by the worker. Samples marked as “area” samples were collected in a fixed location. These samples give an idea of average contaminant concentration at the fixed location but do not necessarily represent worker exposure levels.
All exposures measured were below occupational exposure limits. It is our judgment that exposures will continue to remain low with the following qualifications;
Hydrogen Sulfide Odors
This is an old issue that has been resurfacing periodically. Time-weighted average sampling for hydrogen sulfide using area samplers has been initiated at the southwest corner of the site in response to odor complaints from that area. We should have results from this monitoring within the next few days. It appears that the odors are coming fi-om storm sewer openings in the area. While elevated concentrations of hydrogen sulfide have been periodically found inside the sewer using a remote sampling direct reading instrument, concentrations in work and traffic areas surrounding the sewer openings have been non-detectable.
I know of no reason why these storm sewers would need to be entered, but keep in mind that this sewer system is obviously a permit-required confined space. Be certain that ail workers know that these sewers are confined spaces and should not be entered.
Carbon Monoxide
Carbon monoxide (CO) exposures may increase because more work is being done below grade leveL Although the “fires” are dwindling, use of equipment powered with internal combustion engines in depressions can lead to elevated carbon monoxide levels. So far, time-weighted average exposures continue to remain well below the OSHA PEL of 50 ppm.
We have measured occasional short-lived instantaneous peak levels of CO alcove the NIOSH ceiling level guideline of200 ppm. This is not a legally enforceable exposure limit, but it serves as an indication that high levels of CO can occur under certain conditions. Most of the time, peaks last for only 1 minute or less and may simply be the result of exhaust fi-om a passing vehicle. If peaks begin to occur more than once or twice a day or if peak concentrations begin to cause time-weighted average exposures to approach the PEL of 50 ppm, further investigation of carbon monoxide exposures will be performed.
If ventilation is reasonably good, it is not likely that concentrations will be excessive. However, be aware of any internal combustion equipment being used in spaces with restricted ventilation could trap exhaust gases in the space.
CITY_21MC100_002989160
NYC-WTC_000342107
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000357887
Air sample results memorandum; notes on area and personal samples.
6 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000269145
Cover letter with results and explanation of sampling types and conclusions.
6 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322417
Asbestos and general air sampling results below exposure limits.
6 shared non-person entities · 1 shared topics · similarity 0.969
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342088
Industrial hygiene air samples with sulfuric acid exposure and respiratory-protection notes.
6 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342119
Notification about air sample results and contact for questions; highlights exposure levels.
1 shared non-person entities · 1 shared topics · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000388279
Industrial hygiene air sampling results for the World Trade Center recovery area; guidance provided.
4 shared non-person entities · 1 shared topics · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342118
Summary of area and personal samples; notes silica exceedances and ongoing low exposures.
3 shared non-person entities · 1 shared topics · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000388271
Air sampling results for WTC recovery area, with personal and area sample notes.
4 shared non-person entities · 1 shared topics · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000388275
Industrial hygiene air samples results for World Trade Center recovery zone; general guidance included.
4 shared non-person entities · 1 shared topics · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289869
World Trade Center site air sample summary for hydrogen sulfide; week of 11/25 and 12/2.
3 shared non-person entities · 1 shared topics · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000263569
Emergency Management ATC air sample results with hydrogen sulfide, quartz and other substances.
3 shared non-person entities · 1 shared topics · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000337784
Hydrogen sulfide area/ personal samples; notes elevated area result and plan adjustments.
3 shared non-person entities · 1 shared topics · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000269145
Cover letter with results and explanation of sampling types and conclusions.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357887
Air sample results memorandum; notes on area and personal samples.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322417
Asbestos and general air sampling results below exposure limits.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342088
Industrial hygiene air samples with sulfuric acid exposure and respiratory-protection notes.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342119
Notification about air sample results and contact for questions; highlights exposure levels.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342118
Summary of area and personal samples; notes silica exceedances and ongoing low exposures.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000357887
Air sample results memorandum; notes on area and personal samples.
Similar indexed content
NYC-WTC_000269145
Cover letter with results and explanation of sampling types and conclusions.
Similar indexed content
NYC-WTC_000322417
Asbestos and general air sampling results below exposure limits.
Similar indexed content
Industrial hygiene air samples with sulfuric acid exposure and respiratory-protection notes.
Similar indexed content
NYC-WTC_000342119
Notification about air sample results and contact for questions; highlights exposure levels.
Similar indexed content