OSHA SAMPLING RESULTS SUMMARY AS OF 12/11
Asbestos: A total of 869 air monitoring samples for asbestos have been taken. From 9/13 -9/21,
177 samples were taken in the financial district. They were taken on QSHA personnel
as they walked within certain predetermined zones. Results revealed asbestos
concentrations ranging from ND (none detected) to .037 free., well below OSHA’s
permissible exposure limit (PEL) of. 1 free.
After 9/21, sampling focused on the rubble pile and those workers working on or
immediately next to it. 82 of the samples analyzed exceeded OSHA’s limit via PCM
analysis. However, upon further analysis using discriminating counting methods and/or
TEM analysis, the number of asbestos fibers found dropped dramatically to below
detectable levels or well below .1 free.
Carbon Monoxide: A total of 77 personal samples of workers on the rubble pile showed results ranging
from 1 ppm to 34 ppm which are well below the OSHA 50 ppm permissible exposure
limit.
Noise: OSHA has been conducting noise monitoring in the rubble pile. 18 personal samples
have been conducted on employees performing (or working near) various operations
such as jack hammering, drilling and equipment operations. Employee’s exposure to
the noise range from 73.7 dBA to 94.5 dBA. OSHA’s permissible noise exposure for
construction is 90 dBA. One personal sample and one area sample during core drilling
operations exceeded the OSHA noise PEL of 90 dBA. OSHA continues to recommend
the use of appropriate hearing protection for workers performing tasks where high noise
levels are likely to be encountered.
Respirable
Silica: The overwhelming majority of the 341 silica samples show no detectable levels of
airborne silica. However, nine exposures exceeded the PEL. The highest sample result
was approximately nine times the OSHA limit (pre-drillers working on the slurry or
“bathtub” wall). The other eight exposures were approximately one to six times the
OSHA limit. These exposures occuned during: 1) rubble removal and loading
operations near the Winter Garden; 2) during the breaking up of concrete in the pit; 3)
while core drilling tire concrete slurry wall, and 4) while chipping concrete with power
tools during demolition activities at 7 WTC’s parking garage. Most of the work areas
where apparent overexposures to silica occurred were in the rubble pile; an area where
OSHA continues to encourage the use of respiratory protection.
Volatile Organic
Compounds: OSHA has taken 558 samples for (VOCs) such as acetaldehyde, acrolein, acrylonitrile,
benzene, 2-butanone, carbofurans, chlorodiphenyl (PCB), ethyl benzene, formaldehyde,
Freon R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI),
perchloroethylene, phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl
chloride, and xylene. Screening samples initially showed elevated levels of some
organic chemicals resulting from the fires burning in the rubble pile. Subsequent
personal and area samples show worker exposure levels to be below OSHA limits.
However, one personal sample result for benzene was found to be at the 8-hr. OSHA .
Allowable Limit concentration of 1 ppm. This was found on a backhoe operator moving