OSHA SAMPLING RESULTS SUMMARY AS OF 12/18

Asbestos- A total of 872 an momtonng sarrples for asbestos have been taken From 9/13 -9/21, 177 sarrples were taken m the financial district. They were taken on OSHA personnel as they walked within certam predetermined zones. Results revealed asbestos concentrations rangmg from ND (none detected) to .037 fZcc., well below OSHA’s permissible exposure limit (PEL) of .1 f/cc. After 9/21, sampling focused on fee rubble pile and feose workeis workmg on or immediately next to it 82 of fee sanples analyzed exceeded OSHA’s limit via PCM analysis. However, upon further analysis using discrimmatmg countmg methods and/or TEM analysis, fee number of asbestos fibers found dropped dramaocally to below detectable levels or well below .1 ficc.

Carbon Monoxide: A total of 77 personal sarrples of workers on fee rubble pile showed results ranging from 1 ppm to 34 ppm vdiich are well below fee OSHA 50 ppm permissible exposure limit

Noise: OSHA has been conducting noise monitoring in the rubble pile. 41 personal samples have been conducted on en^iloyees perfoimmg (or working near) various operations such as jack hammering, drilling and equipment operations. Enployee’s exposure to the noise range from 73.7 dBA to 94.5 dBA. OSHA’s permissible noise exposure for construction is 90 dBA. One personal sample and one area sample durmg core drillmg operations exceeded the OSHA noise PEL of 90 d£A. OSHA contmues to recommend the use of appropriate heaimg protection for workers performing tasks where high noise levels are likely to be encountered. Respirable Silica: The overwhelming majority of the 391 silica samples show no detectable levels of airborne silica. However, thirteen exposures exceeded the PEL. The highest sample result was approximately nine tunes the OSHA limit (pre-drillers workmg on the slurry or ‘bathtub” wall). The other twelve elevated exposures were approximately one to six times fee OSHA limit These exposures occurred durmg: 1) rubble removal and loading operations near the Winter Garden; 2) durmg the breakmg up of concrete m the pit; 3) while core drillmg fee concrete slurry wall, and 4) while chipping concrete wife power tools durmg demolition activities at 7 WTC’s parking garage. Most of the work areas where ^parent overexposures to sUica occurred were in the rubble pile; an area where OSHA contmues to encourage fee use of respiratory protection. Volatile Organic Compounds: OSHA has taken 590 sarrples for (VOCs) such as acetaldehyde, acrolein, acrylonitrile, benzene, 2-butanone, carbofurans, chlorodiphenyl (PCB), ethyl benzene, formaldehyde. Freon R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI), perchloroethylene, phosgene, styrene, toluene, 1-3 butadiene, tnchloroethylene, vinyl chlonde, glutaraldehyde, and xylene. Screening sanqiles initially showed elevated levels of some orgamc chemicals resultmg from the fires bunung m the nibble pile. Subsequent personal and area sanqjles show worker exposure levels to be below OSHA limits. However, one personal sample result for benzene was found to be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found on a backhoe operator moving debns See information below for polynuclear aromatics. Freon R-22, phosgene and dioxin. Oxides of Nitrogen/ Sulfur: Sampling on grappier operators on the rubble pile, and on employees manning truck wash stations revealed trace levels of mtnc oxide and nitrogen dioxide. SO, personal and area results were found to be below OSHA limits.

Page 1 of 2

CITY_21MC100_0 10413566

NYC-WTC_000340999

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340999Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →