NYC 9/11 Public Portal Document
OSHA SAMPLING RESULTS SUMMARY AS OF 12/18
Asbestos: A total of 872 air monitoring samples for asbestos have been taken. From 9/13 -9/21, 177
sairples were taken in the financial district. They were taken on OSHA personnel as they
walked within certain predetermined zones. Results revealed asbestos concentrations ranging
from ND (none detected) to .037 free., weU below OSHA’s permissiible exposure limit (PEL)
of .1 free. After 9/21, sampUng focused on the rubble pile and those workers working on or
immediately next to it. 82 of die samples smalyzed exceeded OSHA's limit via PCM analysis.
However, upon further analysis using disemminating counting methods and/or TEM analysis,
the number of asbestos fibers found dropped dramatically to below detectable levels or well
below. 1 free.
Carbon Monoxide: A total of 77 personal samples of workeis on the rubble pile showe d results ranging from 1
ppm to 34 ppm which are well below tire OSHA 50 ppm permissible exposure limit
Noise: OSHA has been conducting noise monitoring in the rubble pile. 41 personal sair^les have been
conducted on employees performing (or working near) various operations such as jack
hammering, drilling and equipment operations. Employee’s exposme to the noise range from
73.7 dBA to 94.5 dBA. OSHA’s permissible noise exposure for construction is 90 dBA. One
personal sample and one area sample during core drilling operations exceeded the OSHA noise
PEL of 90 dBA. OSHA continues to recommend die use of appropriate hearing protection
for workers performing tasks where high noise levels are likely to be encountered.
Respirable
Silica: The overwhelming majority of the 391 sTica samples show no detectable levels of airborne
silica. However, thirteen exposures exceeded the PEL. The hij^est sample result was
approximately nine times the OSILV limit (pre-drillers working on die slurry or “bathtub”
wall). The other twelve elevated exposm es were approximately one to six times the OSHA
limit These exposures occurred during: 1) rubble removal and loading operations near the
Winter Garden; 2) during the breaking up of concrete in the pit; 3) while core drilling the
concrete slurry wall, and 4) while chip])ing concrete with power tools during demolition
activities at 7 WTC’s parking garage. Most of the work areas where apparent overexposures
to silica occurred were in the rubble pile; iin area where OSHA continues to encourage the use
of respiratory protection.
Volatile Organic
Compounds: OSHA has taken 590 sanpies for (VOCs) such as acetaldehyde, acrolein, acrylonitrile,
benzene, 2-butanone, carbofurans, cMorodiphenyl (PCB), ethylbenzene, formaldehyde. Freon
R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI), perchloroethylene,
phosgene, styrene, toluene, 1-3 butadiene;, trichloroethylene, vinyl chloride, glutaraldehyde,
and xylene. Screening sanpies initially showed elevated levels of some organic chemicals
resulting from the fires burning in the rubble pile. Subsequent personal and area sanpies show
worker exposure levels to be below OSHA limits. However, one personal sanple result for
benzene was found to be at the 8-hr. OSH/i Allowable Limit concentration of 1 ppm. This was
found on a backhoe operator moving debris. See information below forpolynucleisr aromatics.
Freon R-22, phosgene and dioxin.
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rabble pile, and on employees manning truck wash
stations revealed trace levels of nitric oxide and nitrogen dioxide. SOj personal and area
results were found to be below OSHA. lirrits.
Page 1 of 2
CITY_21MC100_011109453
NYC-WTC_000276804
OCR can misread numbers and units. Confirm readings against the page image before using them.