OSHA SAMPLING RESULTS SUMMARY AS OF 12/20
Asbestos: A total of 872 air monitoring sanpies for asbestos have been taken. From 9/13 -9/21, 177
sanpies were taken in the financial district They were taken on OSHA personnel as they
walked within certain predetermined zones. Results revealed asbestos concentrations ranging
from ND (none detected) to .037 free., well below OSHA’s permissible exposure limit (PEL)
of .1 free. After 9/21, sampling focused on the rubble pUe and those workers working on or
immediately next to it. 82 of the samples analyzed exceeded OSHA’s limit via PCM analysis.
However, upon further analysis using discriminating counting methods and/or TEM analysis,
the number of asbestos fibers found dropped dramatically to below detectable levels or well
below .1 free.
Carbon Monoxide: A total of 77 personal samples of workers on the rubble pile showed results ranging from 1
ppm to 34 ppm which are well below the OSHA 50 ppm permissible exposure limit
Noise: OSHA has been conducting noise monitoring in the rubble pile. 41 personal sanples have been
conducted on employees performing (or working near) various- operations such as jack
hammering, drilling and equipment operations. Employee’s exposure to the noise range from
73.7 dBA to 94.5 dBA. OSHA’s permissible noise exposure for construction is 90 dBA. One
personal sanple and one area sample during core drilling operations exceeded the OSHA noise
PEL of 90 dBA. OSHA continues to recommend the use of appropriate hearing protection
for workers performing tasks where high noise levels are likely to be encountered.
Respirable
Silica: The overwhelming majority of the 402 silica samples show no detectable levels of airborne
silica. However, fourteen exposures exceeded the PEL. The highest sample result was
approximately nine times the OSHA limit (pre-drillers working on the slurry or “bathtub”
wall). The other twelve elevated exposures were approximately one to seven times the OSHA
limit. These exposures occurred during: 1) rubble removal and loading operations near the
Winter Garden; 2) during the breaking up of concrete in the pit; 3) while core drilling the
concrete slurry wall, and 4) while chipping concrete with power tools during demolition
activities at 7 WTC’s parking garage. Most of the work areas where apparent overexposures
to silica occurred were in the rubble pile; an area where OSHA continues to encourage the use
of respiratory protection.
Volatile Organic
Compounds: OSHA has taken 608 samples for (VOCs) such as acetaldehyde, acrolein, acrylonitrile,
benzene, 2-butanone, carbofurans, chlorodiphenyl (PCB), ethylbenzene, formaldehyde. Freon
R-22 (chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI), perchloroethylene,
phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl chloride, glutaraldehyde,
and xylene. Screening samples initially showed elevated levels of some organic chemicals
resulting from the fires burning in the rubble pile. Subsequent personal and area samples show
worker exposure levels to be below OSHA limits. However, one personal sample result for
benzene was found to be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was
found on a backhoe operator moving debris. See information below for polynuclear aromatics.
Freon R-22, phosgene and dioxin.
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees manning truck wash
stations revealed trace levels of nitric oxide and nitrogen dioxide. SOj personal and area
results were found to be below OSHA limits.