OSHA WTC Sampling Results Page 1 of 4
r 1 U.S. Department of Labor Occupational Safety & Health Administration
4 www.osha.gov j Search| Advanced Search I A-Z Index
OSHA SAMPLING RESULTS SUMMARY AS OF 10/08/2002
Asbestos
A total of 1425 samples (excluding bulk and blank samples) for asbestos have been taken. From 9/13 -9/21, 168 samples were taken in the financial district. Since 9/21, sampling focused on the debris field and those workers working in or immediately next to it. 179 of the samples analyzed exceeded OSHA's limit via PCM analysis. However, upon further analysis using discriminating counting methods and/or TEM analysis, the number of asbestos fibers found dropped dramatically to below detectable levels or well below .1 f/cc.
Carbon Monoxide
127 personal samples of workers on the rubble pile or during demolition operations generally were well below the OSHA permissible exposure limit of 50 PPM. However 2 workers who were both operating gas powered saws near a gas generator were found to be exposed to 73 and 58 ppm up, respectively.
Noise
OSHA is monitoring the noise exposures of employees who perform (or work near) noisy operations such as jack hammering and drilling. To date the 253 samples collected indicate that employee noise exposures range from 73.7 dBA to 110.7 dBA. Sixty-eight samples have exceeded the applicable permissible exposure limit of 90 dBA, mostly for concrete drilling, cutting, and jack-hammering operations. Accordingly, OSHA continues to recommend the use of appropriate hearing protection in noisy operations, and specifically, for concrete drilling, cutting, and jack-hammering operations OSHA recommends dual hearing protection i.e. plugs and ear muff protection.
o Total Dust (PNOR) 1-3
I A total of 176 samples (excluding bulk and blank samples) for total dust in and around the debris field were taken. 5
s a samples were found to be in excess of the PEL for Total dust (ISmg/m^). The highest exposure was found on one operator who was exposed at approximately 4X PEL. o o Respirable Silica I o The overwhelming majority of 1353 silica samples (excluding bulk and blank samples) show no detectable levels of cn LT) http://www.osha.gov/nyc-disaster/summary.html 10/20/2003 S
NYC-WTC_000199923
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186519
Summary of OSHA air monitoring results for asbestos and dust at the World Trade Center site as of February 20, 2002.
24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗24 shared non-person entities · 1 shared topics · similarity 0.983
machine-extracted · confidence unavailable · Check page ↗24 shared non-person entities · 1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149936
Joint OSHA and Bechtel crane inspection report analyzing safety conditions at the World Trade Center site.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content
Similar indexed content