NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Memo: Indoor air quality report, PS 89M, Jun 2002

Machine-extracted title · confidence 32%

ATC report of indoor air quality measurements at P.S. 89M, June 2002.

NYC-WTC_000340521–000340524
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OL<97/2OO2 J,O:58 FAX 212 353 8306 ATC 121004/014

Mr, Bernard P. Orlan June 7, 2002 Indoor Air Quality Assessment Pages P- S. 89M_______________________________ ATC Project No. 15-19125-0297 Real-Time Envirowmental meastbements

ATC collected seventy-nine (SO) sets of real-time environmental measurements consisting of seventy (70) from inside the school building and ten (10) from outdoors. All five floors of the school building were surveyed. These results are described below.

Field data sheets are found in Attachment 1. Readings began at 8:00 A.M. and concluded at approximately 10:50 A.M

T&rwerature

Indoor dry bulb temperature measurements ranged from 71.6 "F to 74.7 °F. Thirty-six (36) of the indoor measurements for temperature were below and none of the measurements were above the range of 73 to 79°F (at 50 percent relative humidity) as recommended by the ASHRAF Standard 55-1992 during the summer season, The outdoor temperature measurements ranged from 73 °F to 73.1 °F,

/ielatiy? .Humidity

The relative humidity indoors ranged from 47.6 to 60.1 percent.' One (1) of the indoor measurements for relative huroidity was above and none of the measurements were below the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 78.6 to 79.2 percent.

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 546 ppm to 1346 ppm. All of the indoor measurements for CO2 was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above tire background level. The maximum outdoor (Irackground) CO2 concentration was 676 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1376 ppm (background level + 700 ppm). Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of CO2 indoors is occupant respiration. The school building was occupied during ATC’s assessment.

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors was 2 ppm for all readings. These concentrations were below the NPAAQS/AStlRAE guideline of 9 ppm. The outdoor CO concentrations was 2 ppm for all collected readings.

Respirable Particulates (PM2.5)

Respirable particulate concentrations’* indoors ranged between 9 p.g/m^ to 22 pg/ra^. The average PM2.5 concentration for die entire school buildmg was approximately 14 pg/m^. All of the indoor measurements were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and tire USEPA recommended concentration of 40 pg/m^ for sensitive individuals and clhldren. The outdoor respirable particulate concentration measurements ranged between 90 pg/m^ to 94 g/m^ with an average of 92

CITY_21MC1OO_OO926149O

NYC-WTC_000340523

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340523Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →