WlO/2002 11:21 FAX 212 353 8306 ATC ® 004

Mr, Bernard P. Orlan June 10, 2002 Indoor Air Quality Assessment Pages P.S.89M . ___________________________ ATCProiectNo. 15-19125-0297 Real-Time Environmental Measurements

ATC collected seventy-nine (80) sets of real-time environmental measurements consisting of seventy (70) from inside die school building and ten (10) from outdoors. All five floors of the school building were surveyed. These results are described below.

Field data sheets are found in Attachment 1. Readings began at 8:01 A,M- and concluded at approximately 09:31 A.M.

Temrterature

Indoor dry bulb temperature measurements ranged from 65.3 ’F to 74.8 ’F. Seventeen (17) of the indoor measurements for temperature were below and none of the measurements were above tlie range of 73 to 79’F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the summer season. The outdoor temperature measurements ranged from. 60.1 “F to 60.3 °F.

Relative Humidity

The relative humidity indoors ranged from 46.1 to 63.7 percent. Ten (10) of the indoor measurements for relative humidity were above and none of the measurements were below the ASHRAE-recoramended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements ranged from 60.8 to 60.9 percent.

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 571 ppm to 1311 ppm. All Of the indoor measurements for CO2 were bellow the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 660 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1360 ppm (background level + 700 ppm). Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of CO? indoors is occupant respiration. The school building was occupied during ATC’s assessment.

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors were 1 pptn for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations were 1 ppm for all collected readings.

Respirable Particulates (PM2j)

Respirable particulate concentrations* indoors ranged between 8 pg/m^ to 16 pg/m^. The average PM2.5 concentration for the entire school building was approximately 12 pg/m^. All of die indoor measurements were below the NPAAQS of 65 pg/m3 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged between 12 pg/m^ to 16 g/m^ with an average of 15 pg/m^.

CITY_21MC100_012158220 NYC-WTC_000340511

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340511Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →