NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 44 pages

OSHA Part 56 asbestos regulations text

Machine-extracted title · confidence 32%

New York DOSH Part 56 asbestos regulations and definitions.

NYC-WTC_000340368–000340411
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYSDOL - DOSH Regulations - Reg Page 40 of 44 monitoring, a minimum of three samples inside and three samples outside the work area shall be taken.

(e) Placement of air-sampling equipment. Air-sampling equipment shall not be placed in comers of rooms or near obstructions. Within the above constraints, samplers shall be placed at random around the work area. If the work area contains the number of rooms equivalent to the number of required samples based on floor area, place a sampler in each room. When the number of rooms is greater than the required number of samples, a representative sample of rooms shall be selected.

(!) Aggressive sampling techniques.The following aggressive sampling techniques shall be used for all clearance air monitoring:

(1) Presampling agitation. Before starting the sampling pumps, the exhaust of forced-air equipment shall be directed against all walls, ceilings, floors, ledges and other surfaces in the rooms. This shall continue for at least five minutes per 1,000 square feet of floor.

(2) Ongoing agitation. At least a 20-inch fan shall be placed in the center of each room. One fan per 10,000 cubic feet of room space shall be used. The fan shall be operated on slow speed and pointed toward the ceiling.

(3) Begin sampling. The sampling pumps shall then be turned on.

(4) End sampling. When sampling has been completed, the sampling pumps shall be turned off first, followed by the fan.

(g) Air changes.During clearance air monitoring, the negative air pressure equipment shall be operated at a maximum of two air changes per hour.

(h) Samplers outside of the work area.For clearance air monitoring, the samplers, placed outside the work area but within the building or structure, shall be so located as to avoid any air that might escape through the isolation barriers.

Note: Minimum distances should be at least 50 feet from the entrance to the work area and 25 feet from the plastic barriers.

(i) Placement of outdoor samplers.Outdoor background samplers shall be placed at approximately grade level six feet above and away from obstructions that may influence wind patterns. If access to electricity and concerns about security dictate a rooftop site, locations near vents or other structures on the roof shall be avoided.

Historical Note: Sec. filed July 7, 1987; amd. filed Oct. 18, 1991 eff. Jan. 1, 1992. § 56-17.3 Air sampling during abatement.

(a) oject shall be conducted in accordance with all requirements of this Part.

Historical Note: Sec. filed Oct. 18, 1991; amd. filed Oct. 25, 1994 eff. Nov. 9, 1994. § 56-3.2 Emergency-general

Note: The size of the abatement activity will determine the number of samples necessary.

(1) Two area samples shall be taken outside the work area and the enclosures, but within the building or structure, in uncontaminated areas that are within 10 feet of the isolation barriers. Where negative ventilation exhaust ducts run through uncontaminated areas, one of the area samples shall be taken in one of these areas. http://www.labor.state.ny.us/html/safety/s56.htm 01/20/2001

CITY_21MC100_012156432

NYC-WTC_000340407

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340407Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446470

State Part 56 asbestos chain-of-custody/document referencing NY Department of Labor; NYC files.

Similar indexed content

Compare copies and versions →