NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 176 pages

Technology overview, NYC health lab report

Machine-extracted title · confidence 25%

Laboratory note on technology tools; unclear project context.

NYC-WTC_000338737–000338912
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Article I Smith et al

bottom of the cage. Holes were placed evenly Teflon filters were weighed, they were ana­ Sciences, Inc., Swedesboro, NJ). Macrophages, along the exit tubes to draw air out along the lyzed by X-ray fluorescence to determine the neutrophils, and lymphocytes were counted length of the chamber. To rest airflow through concentrations of particle-bound trace using light microscopy (1,000 cells/sample). rhe chambers, before their use in Fresno, smoke elements and metals. Statistics. Each experiment consisted of a was admitted into the chamber and observed as Concentrations of inorganic ions (i.e., sul­ filtered air—exposed group and a CAPs- it moved from the top to the bottom exit tubes. fate and nitrate), elemental carbon (EC), and exposed group for all 6 weeks. The data were Repeated testing demonstrated filling and emp­ organic carbon (OC) were determined by col­ analyzed by analysis of variance. Comparisons tying of the chamber with smoke was evenly lecting particles on 37-mm prebaked quartz among exposure groups were evaluated by distributed from the top to bottom of each filters (Pallflex Corp., Putnam, CT). Particles Fisher’s protected least significant difference chamber. Airflow ranging from 2 L/min to 15 were collected on quartz filters at a flow rate of test. Comparisons were considered significant L/min demonstrated uniform mixing of smoke 1 L/min, parallel to the Teflon filter used for if a value of />< 0.05 was obseived. Statistical particles throughout the chamber. gravimetric and metal analysis. At the end of analysis was performed with StatView 5.0.1 During the studies in Fresno, the system each 3-day experiment, a 1 -cnT circular sec­ (SAS Institute Inc., Cary, NC). was operated at a negative pressure (up to 7 tion of the quartz filter was removed from the inches of water) to deliver fine and ultrafine center of the filter and analyzed by thermo­ Results aerosols with minimal loss. Each chamber has analysis to determine EC and OC content Characterization ofexposure chambers. To test an independent flow regulator with the total using a process described in detail by Fung the exposure chambers, the flow rate through flow from the four chambers equal to the (1990). The remainder of the filter was each exposure chamber was set at 2.5 L/min, total output of the VACES. extracted using a mixture of 0.1 mL of ethanol and fluorescein particles were generated with a Physicochemical characteristics of concen­ and 5 mL of distilled deionized water and ana­ nebulizer. Particles were heated and passed trated PM. Animal exposures to concentrated lyzed by ion chromatography to determine the through a diffusion dryer to remove water fine and ultrafme PM in Fresno are summa­ concentrations of sulfate and nitrate. Particle vapor. Particles were collected by placing rized in Table 1. Experiments were conducted number concentrations were measured contin­ round microscope cover slips on six cooled during 3 consecutive weeks in the fall of 2000 uously throughout each exposure period with brass rods. The microscope slides were placed and 3 consecutive weeks in the winter of 2001. a TSI 3022 condensation particle counter, in pH 10 water and counted in a fluoromieter. Each week animals were exposed for 4 hr/day sampling at a flow rate of 0.3 L/min. The large particles [3.1 pm mass median aero­ for 3 days. Of the 10 L/min of concentrated BAL fiuiii analysis. Immediately after dynamic diameter (MMAD)] were collected aerosol generated, 2.3 L/min was diverted into exposure on the third day, rats were anes­ on the cover slips and showed 13% variability. a sampling manifold to determine physical and thetized by intraperitoneal injection of pento­ Smaller particles, with a MMAD of 0.56 pm, chemical characteristics of the exposure aerosol, barbital (100-150 mg/kg body weight) and were generated and showed 10% variability. and the remaining 7.7 L/min was supplied to exsanguinated via the abdominal aorta. The Cages were swabbed, and the swabs were ana­ the four animal exposure chambers. trachea was cannulated and the lungs lavaged lyzed in a fluorometer but exhibited no activity' Particle mass and elemental composition with Ca’"/\'lT’-free phosphate-buffered saline over background. This demonstrated that par­ were measured by collecting concentrated PM (PBS; pH 7.4) at a volume equal to 35 mL/kg ticles were not depositing on chamber walls. on 37-mm Teflon filters (PTEF, 2-pni pore; body weight. Three in-and-out lavages were Characteristics of concentrated aerosols. Gelman Science, Ann Arbor, Ml) at a flow rate performed using the same fluid. BAL fluid was Physicochemical characteristics of concen­ of 1 L/min. The retention efficiency of these centrifuged at 2,000 rpm for 10 min at 4°C. trated particles during fall 2000 and winter filters, even for the most penetrating particles Supernatant was removed, and the cell pellet 2001 are shown in Figures 3-6 and in (0.2-0.3 um), is > 99%. The Teflon filters was resuspended in Ca‘^/Mg^*-free PBS. Table 2. These data represent averages over were weighed before and after each experiment Resuspended cells (0.1 mL) were used to deter­ each 3-day period for each week of exposure. using a Mettler 5 mictobalance (model MT 5; mine total cell count and viability. Cell viabil­ Exposures during the fall of 2000 demon­ Mettler-Toledo Inc., Highstown, NJ), under ity was measured by exclusion of 0.4% trypan strated remarkably consistent particle num­ controlled relative humidity (40-45%) and blue (Sigma, St. Louis, MO), an indicator of bers, varying between 1.1 x 10^ and 1.2 x 10^ temperature (22-24°C) in the Aerosol irreversible loss of plasma membrane integrity. particles/cm^. However, the average mass con­ Laboratory at the University of Southern A second aliquot of cells was centrifuged using centration of the concentrated aerosol varied California. At the end of each 3-day experi­ a Shandon Cytospin (Thermo Shandon, Inc., substantially, ranging from 260 to 847 pg/m^, ment, filters were stored at constant humidity Pittsburgh, PA) to prepare cell differential as shown in Table 2. Ammonium nitrate and and temperature for 24 hr before weighing to slides. The slides were dried at room tempera­ OC were the most prevalent constituents of ensure removal of particle-bound water. After ture and stained with HEMA 3 (Biochemical concentrated fme/ultrafme PM in Fresno, accounting for approximately 60—80% of the total PM mass. The highest particle mass con­ centration during the fall was observed in the first week, with this week also demonstrating From roof the highest fall concentrations for individual Exhaust PM species, especially nitrates and EC. controls 13- Ammonium nitrate concentration was 24% I of the total PM mass during the second week and 57% of the total PM mass during the Fine and ultrafine s ■« third week of fall. EC concentration during particle concentrator the first week of fall was 10 times higher than ja.o during the next 2 weeks of exposure. OC concentration was relatively consistent over Particle analyzer Exposure chamber the 3-weekfall period, ranging from 80 to 141 Figure 2. CAPS exposure system (see text for detailsl. pg/m^. The concentration of trace metals was

904 VOLUME 1111 NUMBER 7 I June 2003 • Environmental Health Perspectives CITY_21MC100_012178534

NYC-WTC_000338812

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338812Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →