NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 91 pages

Environmental Health Perspectives journal excerpt, 110: Journal issue

Machine-extracted title · confidence 28%

Page from the Journal of Environmental Health Sciences featuring an article or note in volume 110.

NYC-WTC_000348757–000348847
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asthma Occurrence • Exposures to urban air toxics in NYC

for at least 10% of sampling events. Flows Teflon filter samples were collected in HNO3 in step 2. The addition of ethanol were checked before and after all sampling plastic cassettes attached downstream from a eliminated the need for redigestion of the filter, events using calibrated flow meters. No sam­ cyclone with a 2.5 (un aerodynamic-diameter so it was not done for summer samples. This pling was carried out for particles larger than cut point (model KTL, BGI, Inc.) when streamlining of the analytical procedure had 2.5 pm in diameter, nor did we analyze for operated at 4 L/min ± 10%. Flows were no significant impact on the measurements. biologic particles. checked before and after sampling. Filters Recoveries of standards and duplicate preci­ During each sampling week, a total of were weighed pre- and postsampling on a sions were very good in both seasons. three 48-hr sample sets were collected at the microbalance at the Harvard School of Public Diluted digests were analyzed by HR- urban and upwind fixed sites. The first of Health Laboratory after being conditioned in ICP-MS. Winter New York samples were these samples was taken at the same time as a temperature-humidity-controlled environ­ run on the Element (Finnigan-Mat, Breman, the individual indoor and outdoor samples; ment for at least 24 hr (by cracking the petri Germany) at Rutgers University; summer two additional consecutive 48-hr samples dish cover) and statically discharged via a New York digests were tun on the newly were taken thereafter. The objectives for polonium source. purchased Axiom (VG-Elemental, Franklin, obtaining these additional rooftop samples After PM2.5 analyses were complete, filters MA, USA) at LDEO. Data were collected were 2-fold: a) to place the individual per­ were returned to Columbia, where they were for all isotopes of interest at the appropriate sonal, indoor, and outdoor sampling in con­ analyzed inside a class-100 flow bench for resolving power (RP) to avoid isobaric inter­ text of the temporal variability, and h} to reflectance using a smoke stain reflectometer ferences. Be, Ag, Cd, Sn, Sb, Cs, La, Pt, Tl, provide additional outdoor samples for source (model 43D; Diffusion Systems Ltd., and Pb, for which interferences are not a apportionment purposes. London, UK). Prior work (6,7) has demon­ problem, were run at RP 400; Na, Mg, Al, S, VOC samples were collected on multi­ strated that reflectance can be a good proxy Ca, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, and sorbent “Air Toxics” tubes (Perkin-Elmer, for elemental carbon concentrations in out­ Zn, at RP 3,000-4,300; and K, As, and Sc, Inc., Shelton, CT, USA) using the U.S. door filters. Measurements of five separate at RP > 9,300. Indium was added to all sam­ Environmental Protection Agency locations are made on each filter. However, ples, blanks, and standards as an internal Compendium Method TO-17. The tubes because in this method the reflectometer head drift corrector and run in all resolving pow­ were stainless steel and approximately 90 mm may touch the active filter area (potentially ers. Quantification is done by external and (3.5 inches) long and 6.35 mm (0.25 inches) resulting in metals contamination), we internal standardization. in diameter containing 35 mm of Carbopack designed and built a new filter holder that HR-ICP-MS data were drift corrected B (a medium-strength hydrophobic sorbent) touches only the outer plastic ring, holding with indium, quantified, convened to a mass, and 10 mm of Carboxen 1000 (a strong sor­ the filter in a fixed flat geometry. This modifi­ and corrected for blanks. Samples that were bent, slighdy hydrophilic). The mixture of sor­ cation enables reflectance measurements to be below the limit of quantification (LOQ) bent strengths allowed for collection of VOCs made without a significant risk of contaminat­ based on daily procedural blanks were from n-C^ to »-Ci2. The low sampling rate ing the filter for later multielement analysis. flagged. For New York winter samples, ana­ prevented breakthrough and loss of collected However, the reflectance measurement is sen­ lyte mass of the first and second digests was VOCs. A diffusion barrier was developed to sitive to the distance between the reflectome­ combined. All sulfur mass concentrations are prevent sampling by diffusion during the lag ter head and the filter (which is an additional reported as sulfate concentrations, which is time before and after active sampling in the 2.5 mm with our filter holder); consequendy, assumed to be the predominant sulfur species home-based and fixed-site monitors, where to help distinguish our measurements from on the PM2,5 filters. sampling was activated and deactivated by those of others, we will report our reflectance Aldehydes were sampled by the method automatic timers. The diffusion barrier con­ measurements as “modified” absorption coef­ of Fung and Grosjean (5), with air pumped sisted of a small-inner-diameter (0.02 mm) ficients (Abs*). Reflectance measurements are through a cartridge packed with Cjg coated stainless steel tube 200 mm in length. A simi­ expressed as the absorption coefficient in with acidified 2,4-dinitrophenylhydrazine lar diffusion barrier was tested and used in a reciprocal meters times 100,000. (DNPH). Samplers were sealed and refriger­ recent European study (5). Analysis of VOC After reflectance measurements, filters ated before and after use and during ship­ tubes was carried out using a Perkin-Elmer were prepared for multielement analysis by ping. Analyses were performed at the automatic thermal desorber (model 400) con­ magnetic-sector high-resolution inductively Harvard School of Public Health. The nected to a Hewlett Packard 589011 gas chro­ coupled plasma mass spectrometry (HR-ICP- DNPH derivatives (hydrazones) were eluted matograph /5971 mass spectrometer with MS). Filters (with supporting ring removed) with acetonitrile and then analyzed using quanitification software (Hewlett Packard, were microwave extracted in two steps inside high-pressure liquid chromatography (model Palo Alto, CA, USA). Sample tubes were 7-mL Teflon vials, which were placed inside 1100, Hewlett Packard) with an ultraviolet placed on a spiking device (tubing connected microwave vessels containing 10 mL 65% detector (360 nm). External standards were to an ultra-high-purity nitrogen tank with fit­ HNO3. For winter samples, reagents in step 1 used to determine the concentration in the ting for the tube) with carrier flow of 75 were 60 pL water and 200 pL concentrated samples based on the peak area. Laboratory mL/min. Vapor-phase internal standard was HNO3; in step 2 reagents were 100 pL and field blanks were used for quality control injected into the device and the tube was kept HNO3 and 40 pL hydrofluoric acid. After purposes. The concentration of aldehydes in place 5 min. The vapor-phase internal stan­ extraction, the mass of remaining digest solu­ found in blank cartridges was subtracted dard is made from liquid standards in solution tion was calculated gravimetrically and from the sample concentration. The variabil­ (usually methanol) of a known concentration brought up to 5 mL to approximately 5% acid ity of the blank levels was used to determine that ate injected as a known volume into a 2-L strength. The filter was removed, transferred the limit of detection. static dilution bottle. A volume of vapor is to a clean vial, and redigested in the same AERs were measured using the perfluoro­ drawn up with a gas-tight syringe and injected manner. Both the first and second digests carbon technique, which is based on diffu- into the injector-port/spiking device with flow were analyzed. Reagents for summer filters sional sources (continually release of tracer onto the sample tube. Drawing different vol­ were 20 pL ethanol, 60 pL water, and 225 pL gas) and diffusional samplers [capillary umes yields different masses of analytes on concentrated HNO3 in step 1, and 10 pL absorption tubes (CATs)]. The sources were tube and thus different levels of calibration. ethanol, 40 pL hydrofluoric acid, and 100 pL placed in the subject’s home 24-72 hr before

Environmental Health Perspectives • volume 1101 supplement 41 August 2002 541

CITY_21MC100_011966377

NYC-WTC_000348799

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348799Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000250587

Public-facing notes on reducing exposure to smoke and dust from WTC fires.

Similar indexed content

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

Compare copies and versions →