NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 176 pages

Technology overview, NYC health lab report

Machine-extracted title · confidence 25%

Laboratory note on technology tools; unclear project context.

NYC-WTC_000338737–000338912
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Article I PM-induced lung injury in healthy rats

PM and their potential effects on the respira­ 12-hr light/12-hr dark cycle. All animals had (Figure 1). Each line has a 2.5-|Jm cut-point tory system. Concentration of the ambient access to Laboratory Rodent Diet 5001 preimpactor, to remove essentially all of the particles in Fresno by 20-fold allowed for (LabDiet, Brentwood, MO) ad libitum before, particles > 2.5 pm from the flow. PM is drawn controlled exposure of healthy, adult rats to during, and after exposures. All animals had through a saturation-condensation system elevated levels of particles. The intent of this access to water ad libitum, except during each that grows particles to 2—3 pm droplets, which study was to determine if concentrated daily exposure period because of the design of ate then concentrated by virtual impaction fine/ultrafme fractions of ambient I’M;).' ^te the exposure chambers. from a total flow of 220 L/min to a flow of cytotoxic and/or proinflammatory in the Particle concentrator system. Animals were 10 L/min, to concentrate particles by a factor lungs of healthy adult rats. After 3 days of exposed either to room ait passed through an of 22. Two diffusion dryers are used down­ exposure (4 hr/day), we measured broncho­ activated carbon-impregnated filter media pad stream of the virtual impactors to remove alveolar lavage (BAL) cell viability and total (Dayton Electric Manufacturing Co., Niles, IL) excess water vapor and return concentrated cells, as well as the number and relative pro­ or to fine and ultrafine CAPs generated by particles to their original size, before delivering portion of macrophages, neutrophils, and portable concentrators developed over the past them to the exposure chambers. lymphocytes from rats exposed to CAPs. 2 years at the University of Southern California. Detailed laboratory characterization of indi­ These portable Versatile Aerosol Concentration vidual components of the VACES has demon­ Materials and Methods Enrichment Systems (VACES) are based on strated the ability of this system to preserve Animals. We purchased 9-10-week-old male previously described technology (Kim et al. particle mass, number, and chemical species Sprague-Dawley rats, free of respiratory disease, 2000; Sioutas et al. 1999). These systems are during the concentration enrichment process from Harlan (San Diego, CA) and quarantined able to enrich the concentration of particles in (Bum et al. 2001b). Experimental characteriza­ them for 1 week before exposure to F APs. The the complete size range of O.Ol-lO pm by up tion of the VACES demonstrated that concen­ study designation, dates of exposure, age of ani­ to a factor of 40, depending on the output flow tration enrichment is accomplished with high mals, and number of rats per group are shown rate. By incorporating size-selective inlets, the efficiency and minimal particle loss over the in Table 1. Animals were handled in accor­ VACES can provide CAPs In selected size range of particle sizes and chemical composi­ dance with standards established by the U.S. ranges. These systems are compact in size and tions encountered in ambient atmospheres. Animal Welfare Acts as set forth in the modular in design, thus allowing their use in Field evaluation, described by Kim et al. National Institutes of Health guidelines mobile exposure platforms. The performance of (2001a), also demonstrated that volatile species, (Institute of Laboratory Animal Resources these systems has been described in detail by such as ammonium nitrate, are preserved 1996) as well as the Animal Care and Use com­ Kim et al. (2001a, 2001b). throughout the supersaturation and concentra­ mittees of both the University of California, Concentration enrichment of particles tion-enrichment processes. Ultrafine particles Davis and California State University, Fresno. with aerodynamic diameters < 2.5 pm is ate concentrated without substantial changes in The rats were housed in plastic caga.s with accomplished by first drawing air samples their compactnes,s or density, as measured by TEK-Cliip pelleted paper bedding (Harlan through IVO parallel lines, each sampling at fractal dimension analysis (Kim et al. 2001a). Teklad, Madison, Wl) and maintained on a 110 L/min for a total flow of 220 L/min The VACES was installed in the animal vivarium located on the campus of California Table 1. Experimental design showing study designation, exposure dates, age of animals, and number of State University, Fresno. The three-story build­ rats used per group. ing that houses the vivarium is located in the Nc.of rats exposed northeastern section of campus. This location is Study designation CATs exposure dates Age (weeksh Filtered air CAPS close to the secondary Supersite station moni­ First week of fal 17-19 October 2000 W 6 6 tored by the U.S. Environmental Protection Secord week of fall 24-26 October 2000 9 6 6 Agency in Fresno. Ambient air for each expo­ Third week of fall 31 October-2 November 2000 9 6 G sure was drawn from the roof of the building, First week of winter 30 January-1 February 2001 9 6 6 and the aerosol was delivered to the VACES via Second week of winter 6-8 February 2001 9 6 6 an 8-m-long, 7.62-cm-diamcter duct. At a flow Third week of winter 13-15 February 2001 9 6 6 rate of 220 L/min, the aerosol residence time in ^Age of rats at beginning of exposure. the duct before reaching the VACES was about 10 sec, rapid enough to avoid particle loss on 5 L/min the duct walls from deposition by settling (for larger particles) or diffusion (for smaller parti­ Vl-1 cles). The concentrated aerosol was supplied to I 110 L/rniri ; 5 L/min Diffusion whole-body animal exposure chambers. Cooler J------- dryers Fabrication and characterization of expo- 10 L/min Vf-2 sitre chambers. Exposure chambers were con­ I 110 L/min structed using standard animal housing cages 22 times concentrated made of polycarbonate measuring 20 x 43 x 18 PM cm. The metal top of the cage that held food Exposure chamber and water was replaced with a lid designed to deliver aerosols into the chamber (Figure 2). Air Pump passing through the cyclone-designed orifice Deionized water created a circular flow into the chamber. A per­ Saturator forated metal sheet consisting of 1.7-mm-diam- 20-L water 21C L/min eter holes and 23% open area placed in the lid allowed airflow to be distributed along the top Hearing bath of the cage in a uniform manner. Tur was drawn Figure 1. VACES for sampling fine/ultrafine PM. VI, virtual impactors. out of the chamber by two tubes located at the

Environmental Health Perspectives • voluivie 111 I number 7 I June 2003 903 CITY_21MC100_012178533

NYC-WTC_00033881 1

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000338811Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →