from fires and can be expected near the site and in the smoke plume as well. Different sampling techniques are required for these compounds.

Public Health Implications

Although the highest levels of VOCs were found in samples from the plume at the WTC debris pile, these results are not likely to represent the potential exposure of the residents. Residents are unlikely to be in the plume at the debris pile where they could be exposed to these levels for any length of time. Therefore, the sampling results for areas potentially affected by the plume (i.e., at downwind locations) but not at the debris pile are more relevant for evaluating potential exposure to the residents. The levels of some of the chemicals in the plume measured at the debris are elevated and exceed typical background ranges, and recovery and emergency workers should take precautions to limit their exposure to emissions from the plume.

The levels of VOCs at the upwind sites (75 Park Place and 225 Rector) are within the range of typical background levels.

The air concentrations of VOCs at the downwind site (140 Broadway) were generally greater than those measured upwind (75 Park Place and 225 Rector) and typical background concentrations. However, none of the WTC-related chemicals measured at 140 Broadway exceed both typical background levels and air comparison values except benzene, chloromethane and styrene. Based on the available information, exposures to these chemicals from the plume are luilikely to last more than one year. Thus, in addition to typical background levels, the concentrations of the chemicals measured at 140 Broadway are evaluated with health comparison values for air based on noncancer effects and exposure durations of less than one year (e.g., acute (up to two weeks) and intermediate (up to one year) air comparison values).

None of the chemicals detected above background at 140 Broadway exceed intermediate or short-term air comparison values except benzene. The average and highest levels of benzene at 140 Broadway are slightly above typical background and are near the intermediate comparison value for this chemical. This comparison value for benzene is about 90 times lower than the exposure level that caused mild neurological effects in mice exposed regularly for 30 days.

The benzene air concentrations at 140 Broadway (as well as typical background concentrations of benzene) exceed the health comparison value for benzene in air based on carcinogenic effects following long-term exposure. The cancer comparison value is the air concentration associated with an increased lifetime cancer risk of one-in-one million (10'®). Because the estimated duration of exposure is at most one year, and because elevated levels are unlikely to persist for extended periods of time (e.g. the fires will be put out and the wind direction will periodically change), community exposures are not expected to result in cancer risks that are appreciably increased over those resulting from background exposure. These estimated cancer risks do not exceed one-in-ten thousand (10"*), above which actions are usually taken to reduce exposure.

The average levels of chloromethane and styrene also exceed background and their air comparison values based on cancer effects and long-term exposure. Again, based on the low potential for long-term exposure to elevated levels, this is not expected to result in an appreciable increased cancer risk, but one similar to the risks resulting from exposure to background levels.

Limitations of Health Assessment

The primary limitation of this assessment is that the list of VOCs measured may not be completely

3

CITY_21MC100_006753885

NYC-WTC_000337697

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337697Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

VOC monitoring summary near WTC, Sep 28, 2001

NYC-WTC_000204863

Summary report of volatile organic compound monitoring conducted by State and City Health Departments around the World Trade Center site on September 28, 2001.

Similar indexed content

Compare copies and versions →