VOC air sampling report, World Trade Center, Sep 2001

Machine-extracted title · confidence 42%

Air samples at three locations near WTC measured VOCs for screening purposes, analyzed by GC-MS.

NYC-WTC_000337695–000337698
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2. At 75 Park Place (upwind of the WTC site) and at 225 Rector (cross-wind), VOC levels, except ethanol, were in the range of levels commonly found in outdoor air samples (background). At 140 Broadway (downwind), where the smoke plume from the WTC site was visible during each of the sampling events, most of the VOCs detected were greater than background (generally less than five times background levels and all (except trichlorofluoromethane) less than about ten times background levels).

3. Generally, VOC concentrations at 140 Broadway were about 3 times greater than those at Park Place and Rector Place sites.

4. During each of the sampling events, the smoke plume was visibly evident at 140 Broadway and fire odors were noticeable at the street level. During sampling at the other sites, the smoke plume was not visibly evident at the sites. WTC-related odors were sometimes noticed at the Rector Place site and not noticed at the Park Place site.

5. VOC concentrations on the roofs were not substantially different from street-level VOC concentrations at each of the sampling sites, including 140 Broadway (53 stories high).

6. Concentrations of VOCs associated with the smoke plume were about 20 times greater in the grab sample at the pile than at 140 Broadway.

7. High levels of trichlorofluoromethane (a refrigerant, R-11), were observed in the samples from the roof at 140 Broadway. The building manager said that a chiller leak sensor had detected a minor refrigerant leak of R-11 on Friday (Sept 28) morning. The problem was conected later in the day. The chiller is located on the 52"‘* floor and a mechanical room vent was about three meters (10 feet) from the sampler.

8. Elevated methylene chloride concentrations were also detected on the roof of 140 Broadway with slightly higher levels found in the afternoon sample when the chiller was being repaired. Methylene chloride is commonly used as a degreaser in building HVAC system maintenance and repair work. It was not measureable in the plume sample or any of the other samples.

9. The field forms for the morning samples for 140 Broadway (roof and street level) were switched so the laboratory report forms misidentify the roof and street level samples at this location.

10. Because the trichlorofluoromethane and methylene chloride were on the roof top and people are not being directly exposed to them, they are not discussed in the health implications section.

11. Assuming that the fires and smoke will continue to diminish as the recovery work progresses, these data suggest that additional VOC sampling for these compounds is not necessary. However, it may be useful to confirm these findings, to assess levels of other volatile compounds such as known respiratory irritants and to assess VOC concentrations once the fires are controlled to ensure that other recovery activities are not a continuing source of VOCs in the community.

Data Limitations

These VOCs were selected for analysis because they are commonly found at low levels in outdoor and indoor air, routine analytical procedures were readily available and many have been shown to be constituents of fires. Other VOCs and semivolatile organic compounds have been found in the smoke

2

CITY_21MC100_006753884

NYC-WTC_000337696

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337696Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

VOC monitoring summary near WTC, Sep 28, 2001

NYC-WTC_000204863

Summary report of volatile organic compound monitoring conducted by State and City Health Departments around the World Trade Center site on September 28, 2001.

Similar indexed content

Compare copies and versions →