NYC 9/11 Public Portal Document
VOC MONITORING NEAR THE WORLD TRADE CENTER ON SEPTEMBER 28,2001
SUMMARY
To measure the surrounding communities’ exposure to volatile organic compounds (VOCs) from
the World Trade Center fires and cleanup activities, the State and City Health Departments
collected air samples for some VOCs around the World Trade Center. Most of these compounds
are commonly found in petroleum products or are common industrial chemicals. Some of these
compounds are also produced by fires, including the World Trade Center fires, or by equipment,
such as the equipment being used in the recovery effort.
Air samples were taken on September 28, 2001 at three locations around the World Trade Center
site. Samples were taken at roof level and street level. They were taken in the morning,
afternoon and evening. One sample was also taken in the smoke at the wreckage at the World
Trade Center. The sample in the smoke plume had the highest levels of VOCs, Recovery and
emergency workers need to take safety measures that have been provided to them to limit their
exposure to the smoke at the site.
Samples were taken near Parc Place, Rector Place and Broadway at Liberty Streets. Upwind of
the site and crosswind, levels of VOCs were about the same as those commonly found in outdoor
samples (also called “background” levels). Downwind of the site, VOC levels for most of the
compounds detected were higher than background.
The higher levels of VOC compounds downwind of the site are not likely to last for an extended
period of time (for example, the fires will be put out and the wind direction changes). The health
risks from VOCs downwind, where the levels are highest, are still not much different than they
would be for typical background levels. For the VOCs that were measured, the air concentrations
outside the work area are not a significant health concern. However, other chemicals fi’om the
fires or other recovery activities may be contributing to eye, nose and throat irritation.
Hmgle
I WTC
r Site
Albany* /
South End intai
y
roof ««inpla?\
Hactor PI& Broadways
South Enifx/ ZtoSI and street wimple
atraat aimpla
> S. \ X,*' ^11
1 //
'i •
Sampling locations
for VOC monitoring
on September 28,2001
CITY_21MC100_002462972
NYC-VVTC_000337879
OCR can misread numbers and units. Confirm readings against the page image before using them.