NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

ATC sampling summary report, units inspected

Machine-extracted title · confidence 38%

Summary of observations and ambient air sampling at aTribeca building site.

NYC-WTC_000337568–000337570
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

NYC DEP BANHazmat Exec Fax:7185953744 Dec 13 ’01 11:07 P.02

Ambient Air Sampling *SBOCI&T«8 INC.

Flbwrolaas In Air via PCM Twelve ambient air samples collected within the common areas lobby were analyzed for fiberglass using the Phase Contrast Microscopy (PCM) analytical method. All samples collected recorded fiber levels less than 0.01 f/cc In the absence Of e specific ambient air standard for fiberglass. ATC has selected as a criteria for acceptable ambient air sample sets, the NYCDEP re-occupancy requirement following an asbestos abatement action of an average of lees than 0.01 fibers per cubic centimeter (o.ol f/cc’). In conclusion, based upon the analytical results for fiberglass recording fiber concentrations below the NYC acceptable airborne clearance requirement following an abatement action, It Is ATC’e opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy

PCB’g In Air One ambient air sample collected within the lobby and analyzed for PCB's recorded analytical results less than analytical detection limit.

Indoor Air Quality The lAQ evaluation included collection of seventy-five real-time measurements of temperature, relative humidity, carbon dioxide (CO:), carbon monoxide (CO), respirable particulates and total volatile organic compounds (TVOC). Currently, there are no regulatory standards for indoor air quality in non-industrlal buildings, Buch as residential units. For the real-time data collected. ATC uses the commonly.accepted guidelines cited in the following publications: Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999). American Society of Heating, Refrigerating, and Alr-Conditloning Engineers (ASHRAE); e Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); • Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

PARAMETER TARGET LEVEL AGENCY OR ORGANIZATION Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (COa) above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in (CO) ASHRAE 62) _________ Respirable Particles 50 micrograms per cubic USEPA NPAAQS (as cited in (PMio) __________ meter of air (pg/m’) ASHRAE 62) __________ Temperature Summer. 73-79’F at 60% RH ASHRAE 55 Winter 68-75°F at 60% RH Relative Humidity 30 - 60 % ASHRAE 55

CITY_21MC1OO_OO6753256

NYC-WTC_000337569

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337569Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000354099

ATC inspection summary of dust/debris in 406 units; no widespread deposition found.

Similar indexed content

NYC-WTC_000357527

Summary of observations and air/dust sampling at Tribeca Tower for asbestos.

Similar indexed content

ATC dust inspection summary, Dec 2001

NYC-WTC_000199569

Summary of ATC visual inspections and air sampling at a site for WTC-related dust debris as of December 2001.

Similar indexed content

NYC-WTC_000269013

Summary of observations and air sampling during Tribeca Tower inspections.

Similar indexed content

NYC-WTC_000318568

Summary of ATC sampling observations and unit inspections at Tribeca Tower through Dec 11, 2001.

Similar indexed content

Compare copies and versions →