NYC-WTC_000354099
ATC inspection summary of dust/debris in 406 units; no widespread deposition found.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Summary of observations and ambient air sampling at aTribeca building site.
NYC-WTC_000337568–000337570OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
NYC DEP BANHazmat Exec Fax:7185953744 Dec 13 ’01 11:07 P.02
Ambient Air Sampling *SBOCI&T«8 INC.
Flbwrolaas In Air via PCM Twelve ambient air samples collected within the common areas lobby were analyzed for fiberglass using the Phase Contrast Microscopy (PCM) analytical method. All samples collected recorded fiber levels less than 0.01 f/cc In the absence Of e specific ambient air standard for fiberglass. ATC has selected as a criteria for acceptable ambient air sample sets, the NYCDEP re-occupancy requirement following an asbestos abatement action of an average of lees than 0.01 fibers per cubic centimeter (o.ol f/cc’). In conclusion, based upon the analytical results for fiberglass recording fiber concentrations below the NYC acceptable airborne clearance requirement following an abatement action, It Is ATC’e opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy
PCB’g In Air One ambient air sample collected within the lobby and analyzed for PCB's recorded analytical results less than analytical detection limit.
Indoor Air Quality The lAQ evaluation included collection of seventy-five real-time measurements of temperature, relative humidity, carbon dioxide (CO:), carbon monoxide (CO), respirable particulates and total volatile organic compounds (TVOC). Currently, there are no regulatory standards for indoor air quality in non-industrlal buildings, Buch as residential units. For the real-time data collected. ATC uses the commonly.accepted guidelines cited in the following publications: Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999). American Society of Heating, Refrigerating, and Alr-Conditloning Engineers (ASHRAE); e Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); • Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).
PARAMETER TARGET LEVEL AGENCY OR ORGANIZATION Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (COa) above background level Carbon Monoxide 9 ppm USEPA NPAAQS (as cited in (CO) ASHRAE 62) _________ Respirable Particles 50 micrograms per cubic USEPA NPAAQS (as cited in (PMio) __________ meter of air (pg/m’) ASHRAE 62) __________ Temperature Summer. 73-79’F at 60% RH ASHRAE 55 Winter 68-75°F at 60% RH Relative Humidity 30 - 60 % ASHRAE 55
CITY_21MC1OO_OO6753256
NYC-WTC_000337569
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000354099
ATC inspection summary of dust/debris in 406 units; no widespread deposition found.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199569
Summary of ATC visual inspections and air sampling at a site for WTC-related dust debris as of December 2001.
13 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318568
Summary of ATC sampling observations and unit inspections at Tribeca Tower through Dec 11, 2001.
14 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357527
Summary of observations and air/dust sampling at Tribeca Tower for asbestos.
13 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000269013
Summary of observations and air sampling during Tribeca Tower inspections.
13 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363404
Summary of ATC asbestos air sampling results and dust observations at Tribeca Tower.
12 shared non-person entities · 1 shared topics · similarity 0.986
machine-extracted · confidence unavailable · Check page ↗9 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437420
ATC ambient air sampling at 40 Rector Street; contents include procedures and results.
3 shared non-person entities · similarity 0.947
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409106
Chain-of-custody for visual, bulk, and air asbestos sampling at Building 100, dates in 2001.
5 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409194
Chain-of-custody documenting asbestos sampling and air monitoring at Building 500.
5 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409495
ALC inspections including bulk sampling, air sampling on Sept 23, Oct 5, Oct 12, 2001.
5 shared non-person entities · similarity 0.946
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409134
Chain-of-custody for asbestos visual, bulk and air sampling at Building 100, Sep–Oct 2001.
5 shared non-person entities · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000318568
Summary of ATC sampling observations and unit inspections at Tribeca Tower through Dec 11, 2001.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000357527
Summary of observations and air/dust sampling at Tribeca Tower for asbestos.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000269013
Summary of observations and air sampling during Tribeca Tower inspections.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199569
Summary of ATC visual inspections and air sampling at a site for WTC-related dust debris as of December 2001.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363404
Summary of ATC asbestos air sampling results and dust observations at Tribeca Tower.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
ATC inspection summary of dust/debris in 406 units; no widespread deposition found.
Similar indexed content
Summary of observations and air/dust sampling at Tribeca Tower for asbestos.
Similar indexed content
NYC-WTC_000199569
Summary of ATC visual inspections and air sampling at a site for WTC-related dust debris as of December 2001.
Similar indexed content
Summary of observations and air sampling during Tribeca Tower inspections.
Similar indexed content
Summary of ATC sampling observations and unit inspections at Tribeca Tower through Dec 11, 2001.
Similar indexed content