NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

ATC sampling summary report, units inspected

Machine-extracted title · confidence 38%

Summary of observations and ambient air sampling at aTribeca building site.

NYC-WTC_000337568–000337570
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document I NYC DEP BRNHazmat iU.310 Fax •.7185953744 Exec ncun I c-i/ , in, ,r,u.... I Dec 13 ’01 11:06 P. 01

Ambient Air Sampling ASSCCIATtS INC-

To: Related Management Company Subject: Summary of Ambient Air Sampling to Date Re: Trlbeca Tower From; Fred Burkhardt Date: December 11,2001

The following Is a brief summary of the observations, real-time monitoring, and ambient air sampling performed at Trlbeca Tower to date. mt Visual Inspection ATC visually inspected 406 units for accumulated dust and/or debris consistent with material that from ATC's experience emanated from the collapse of the World Trade Center Buildings. Thirty-four units were inaccessible or the occupants refused access and were not inspected. Of the 406 units inspected, ATC did not observe any dust and/or debris accumulations that In ATC's opinion was consistent with widespread deposition of material that emanated from the collapse of the World Trade Center Buildings. However, ATC observed adjacent to open windows In four units, limited dust accumulations (no debris) although inconsistent with material that emanated from the collapse of the World Trade Center Buildings present nonetheless.

Aabeetos Air Sampling vie TEM ATC collected a total of 60 common area and 149 residential unit samples to ascertain the presence or absence of airborne asbestos. - All samples were collected and analyzed in accordance with the AHERA Transmission Electron Microscopy (TEM) method as set forth at 40 CFR Part 763. Subpart E, Appendix A which provides resolution down to O.Sp. structure size. Of the total 209 samples collected, a single asbestos structure was detectable on only two samples. In the absence of a specific ambient air standard, ATC has selected as a criteria for acceptable ambient air sample sets, the AHERA re-occupancy requirement following an asbestos abatement action of an average of less than 70 asbestos structures per square millimeter (<70 s/mm’) per sample set. This criteria has been selected because the AHERA requirement is the most stringent reoccupancy requirement available, and has been designed to be protective of children following an asbestos abatement project. Based upon analytical sample results for all samples recording levels well below the AHERA clearance requirement, it is ATC’s opinion that ths ambient air samples collected throughout the building are representative of the ambient conditions at the time of testing and that the areas tested meet en acceptable criterion for re-occupancy

Poat-tr Fax Note 7571 Date

From CoJOept. Co. b &■/> Phone D Phone »

CITY_21MC100_006753255

NYC-WTC_000337568

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000337568Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000354099

ATC inspection summary of dust/debris in 406 units; no widespread deposition found.

Similar indexed content

NYC-WTC_000357527

Summary of observations and air/dust sampling at Tribeca Tower for asbestos.

Similar indexed content

ATC dust inspection summary, Dec 2001

NYC-WTC_000199569

Summary of ATC visual inspections and air sampling at a site for WTC-related dust debris as of December 2001.

Similar indexed content

NYC-WTC_000269013

Summary of observations and air sampling during Tribeca Tower inspections.

Similar indexed content

NYC-WTC_000318568

Summary of ATC sampling observations and unit inspections at Tribeca Tower through Dec 11, 2001.

Similar indexed content

Compare copies and versions →