Mr. Bernard P. Ori an February 28, 2002 Indoor Air Quality Assessment Page 4 H.S. for Leadership & Pub. Servuce fM894) ATCProiectNo. 15-19125-0290

TVOC Concentration

The TVOCs concentrations was 0 ppm inside the building. These concentrations were below the AIHA guideline for odor control of 1 ppm. The outdoor TVOC concentration was 0.0 ppm.

OBSERVATIONS

During thus assessment, ATC noted the following: • The interior of the building appeared clean and free of dust and debris; • The building was occupied at the time of the assessment; • No smoke odor was detected in the building;

FINDINGS

Based on the real-time measurements, the following findings are presented;

1. Concentrations of CO2, CO and TVOCs, were within applicable standards and guidelines. 2. Ten temperature measurements were below the range of 68 to 75 °F (at 50 percent relative humidity recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 3. Twenty-four (24) of the relative humidity measurements were below the ASHR.AE recommended range of 30 to 60 percent for occupant comfort. 4. None of the indoor respirable particulate measurements were above the EPA recommended guideline for children and sensitive individuals of 40pg/m3 ■ One of the outdoor readings were above the NPAAQS of 65 pg/m3.

.It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 261 or 212.

Sincerely, A TC ASSOCIA TES INC. Reviewed by:

7 6^6^ Ca Yiaimis Efstathiou James R. Cohn, CIH, CSP Project Manager Regional Manager Industrial Hygiene Division

Attachment

CITY_21MC100_003059068

NYC-WTC_000335553

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000335553Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000370407

ATC IAQ measurements conducted March 4, 2002 at the referenced NYC BOE school.

Similar indexed content

NYC-WTC_000370422

Indoor air quality measurements collected March 6, 2002 at the referenced school.

Similar indexed content

Compare copies and versions →