NYC 9/11 Public Portal Document
D5756-95 Standard Test Method for Microvacuum Sampling an4ilpjywww.astm.org/cgi-bin/SoftCarLexe/DATABASE.CART/PAG,.. - a
Other users J
of this
Document Summary standard also
*To order the Juli text, see ordering options at lejt.
downloaded: 9 I
Developed by D5755:
ASTM Test Method D5756-95 Standard Test Method for Standard Test
Subcommittee: Microvacuum Sampling and Indirect Analysis of Method for
D22.07 Microvacuum
Dust by Transmission Electron Microscopy for Sampling and 1
Adoptions: Asbestos Mass Concentration Indirect
Analysis of
Book of Copyright 2001 AMERICAN SOCIETY FOR TESTING AND Dust by
Standards MATERIALS, West Conshohocken, PA. All rights reserved. Transmission
Volume: Electron
li.03 Microscopy for
1. Scope Asbestos
Order Now: Structure
Credit Card Only Number
• Download Full 1.1 This test method covers a procedure to () identify asbestos in Concentrations
Text (PDF) dust and () provide an estimate of the concentration of asbestos in
• Mail Delivery - the sampled dust, reported as either the mass of asbestos per unit D6281:
North America area of sampled surface or as the mass of asbestos per mass of Standard Test
• Mail Delivery - sampled dust. Method for
Internationa Airborne
1.1.1 If an estimate of asbestos structure counts is to be determined, Asbestos
Price: $ 35.00 Concentration
the user is referred to Test Method D5755.
in Ambient and
Pages: 13 Indoor
1.2 This test method describes the equipment and procedures
Atmospheres as
HeloDesk necessary for sampling, by a microvacuum technique, non-airbome
Determined by
dust for levels of asbestos. The non-airbome sample is collected Transmission
inside a standard filter membrane cassette fi-om the sampling of a Electron
surface area for dust which may contain asbestos. Microscopy
Direct Transfer
1.2.1 This procedure uses a microvacuuming sampling technique. (TEM)
The collection efficiency of this technique is unknown. Variability
of collection efficiency for any particular substrate and across D6480:
different types of substrates is also unknown. The effects of Standard Test
Method for
sampling efficiency differences and variability on the interpretation Wipe Sampling
of dust sampling measurements have not been determined. of Surfaces.
Indirect
1.3 Asbestos identified by transmission electron microscopy (TEM) Preparation, and
is based on morphology, selected area electron diffraction (SAED), Analysis for
and energy dispersive X-ray analysis (EDXA). Some information Asbestos
about structure size is also determined. Structure
Number
1.4 This test method is generally applicable for an estimate of the Concentration
concentration of asbestos starting from approximately 0.24 pg of byTransmission
Electron
asbestos per square centimeter (assuming a minimum fiber
Microscopy
dimension of 0.5 [mu]m by 0.025 [mu]m, see 17.8), but will vary
1 of2 1/14/2002 1:13 PM
CITY_21MC100_006763161
NYC-WTC_000332083
OCR can misread numbers and units. Confirm readings against the page image before using them.