D5755-95 Standard Test Method for Microvacuum Sampling an44pi//www.astm.org/cgi-bin/SoftCart.exe/DATABASE.CART/PAG. .
aggregated asbestos into fundamental fibrils, fiber bundles, clusters,
or matrices that can be more accurately quantified by transmission
electron microscopy. However, as with all indirect sample
preparation techniques, the asbestos observed for quantification
may not represent the physical form of the asbestos as sampled.
More specifically, the procedure described neither creates nor
destroys asbestos, but it may alter the physical form of the mineral
fibers.
1.5 The values stated in SI units are to be regarded as the standard.
The values given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety
concerns, if any, associated with its use. It is the responsibility of
the user of this standard to establish appropriate safety and health
practices and determine the applicability of regulatory limitations
prior to use.
2. Referenced Documents
D1193 Specification for Reagent Water
D1739 Test Method for the Collection and Measurement of
Dustfall (Settleable Particulate Matter)
D3195 Practice for Rotameter Calibration
D3670 Guide for Determination of Precision and Bias of Methods
of Committee D-22
D5756 Test Method for Microvacuum Sampling and Indirect
Analysis of Dust by Transmission Electron Microscopy for
Asbestos Mass Concentration