NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis with SAED/EDS; AHERA methods; PS 13OM site across building; 10/19/01.
NYC-WTC_000329868OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identilicatiou by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy [SDS) Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site; P.S. 13OM, 143 Baxter St., NY, NY TEM Sample No.: 5726 - 61678 Throughout the School Building Date Received: i0/:8/01 Grid Openings Analyzed; 4
Project Sample No. Average Grid Oreninc: 106.00 urr
Air Vnlump: 19 08 Hters Total Area Analyzed: C.C45C mn2
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity:22,2 s/rrm2 Effective Area; 38 5 'nin2 U.0045 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >«5um Struct/mm2 Struct/cc nqm/Tn3
Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos I includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos c c 0 0 0 0 0.0 0.0000 N/A No Identificatton 0 c 0 0 0 0 0.0 0.0000 N/A •
Totals (All Structures) 0 0 0.0 0.oooc N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestcs fiber i.d. (EDS/SA.ED) : None detected Amphibole Asbestos Type; None detected The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Revievzed by;
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003273882
NYC-WTC_000329868
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324074
TEM analysis with SAED/EDS; AHERA method applied to PS 130M site.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411526
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329855
TEM asbestos analysis data for PS 130M school building.
8 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411534
TEM SAED/EDS asbestos fiber analysis for PS 234M, October 1987.
6 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202619
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411531
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
5 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324074
TEM analysis with SAED/EDS; AHERA method applied to PS 130M site.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similar indexed content
NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
Similar indexed content
NYC-WTC_000329848
Asbestos fiber analysis by TEM for PS 130M school.
Similar indexed content
NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
Similar indexed content
NYC-WTC_000324074
TEM analysis with SAED/EDS; AHERA method applied to PS 130M site.
Similar indexed content