Asbestos TEM analysis, PS 130M, Oct 2001

Machine-extracted title · confidence 37%

TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.

NYC-WTC_000329867
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28--11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, ERA Federal Register (40 CFR, Part 763). Vol. 52. No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site• P S 130M, 143 Baxte- St , NY, NY TEM Sample No.: 5726 61675 Throughout the School Building Date Received :10/Jl^/01. Grid Openings Analyzed: 4

Project Sample No.: 20 Average Grid Opening: 106 .DC um

Air Volume: 1S08 liters Tcta'j Area Analyzed: 0.04 50 mmO

Filter Type: MCE 25 mm diam., Pore Size: 0.4= um Analytical Sensitivity: 22.2 s,^mm2 Effective Area: 365 mm2 UU45 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total, Struct. Filter Air Fibers Bundles Clusters Struct. Struct :> = 5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0. 0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.oooo 0

Total asbestos (includes ambiguous structures) 0 0 0. 0 0.ococ 0 Non-Asbestos 0 0 0 0 9 0 0.0 0.0000 h’/A No Identification 0 0 0 0 0 0.0 0.0000 n7a

Totals (All Structures) 0 0.0 0.0000 n7a The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole /asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEN method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by;

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003273879

NYC-WTC_000329867

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000329867Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →