NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
4 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis with SAED/EDS for PS 13QM site; project/site: throughout school building; date 10/18/01.
NYC-WTC_000329865OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY tTEM) With Fiber Identification by Selected-Area Electron Diffraction (SAEDl and Energy-Dispersive X-RAY Spectroscopy IEDS) Method: AHERA Final Rule, EPA Federal Register {40 CFR, Part 763), Vol. 52, No. 210. October 30, 1987
Sample Identification Analysis Parameters
ProTect/Site: P.S. 13QM. 143 Baxter 5t., NY, NY T2M Sample No.: 5726 61673 Throughout the School Building Date Received: 10/18/01 Grid Openings Analyzed: 4
Project Sample No.: 18 Average Grid Opening: 106.00 um
Air Volume: 1917 liters Total Area .Analyzed. :0;0450 rnrr^
Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analyt i ca1 Sensit ivi ty: 22.2 g/mmS Effective Area: 385 mm2 O.OC'45 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mml nqm/mS
Chrys oti1e Asbe st os 0 0 0 0 0 0.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0.0 G.QOOO 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbesto‘s 0 0 0 0 0 0 c.o 0.0000 N/a No Identification 0 c 0 0 0 0 0.0 0.0000 N/a
Totals (All Struutures) 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with, the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by:
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003273877
NYC-WTC_000329865
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
4 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
5 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262777
TEM asbestos analysis at PS 234M; SAED/EDS identification, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329854
AHERA TEM-based asbestos analysis for PS 130M site.
5 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202619
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
5 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329855
TEM asbestos analysis data for PS 130M school building.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411526
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329853
TEM asbestos analysis results, PS 130M building-wide.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411536
TEM asbestos analysis results for PS 234M site, October 2001.
6 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329864
TEM-based identification of asbestos fibers with SAED/EDS for project site PS 130M/PS 13OM in Oct 2001.
5 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262777
TEM asbestos analysis at PS 234M; SAED/EDS identification, Oct 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329854
AHERA TEM-based asbestos analysis for PS 130M site.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202619
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000329867
TEM asbestos analysis; SAED/EDS identification; project/site PS 130M, throughout building; 10/19/01.
Similar indexed content
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similar indexed content
NYC-WTC_000262777
TEM asbestos analysis at PS 234M; SAED/EDS identification, Oct 2001.
Similar indexed content
NYC-WTC_000329854
AHERA TEM-based asbestos analysis for PS 130M site.
Similar indexed content
NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
Similar indexed content