ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA FinaZ Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52. No. 210, October 30. 1987

Sample Identification Analvsos Parameters

Project/Site; P.5. 130M, 143 Baxter St., NY, KY TEM Sample No . :_5726_^_61671 Throughout the School Building Date Received: 10/16/01 Grid Openings Analyzed:__ 4

Project Sample No.: 16 Average Grid Qneninq: 106.00 um

Air Volume ;ie991it^^ Total Area Analyzed: 0.0450 mn2

Filter Tvoe: MCE 25 mm diam. Pore Size; 0.45 utt Analytical Sensitivity: 22,2 s/mm2 Effective Area: 385 mm2 0,0045 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5uTn Struct/mrr.2 Struct/cc nqm/rri3

Chrysotile Asbestos 0 0 0 0 0 0 0. 0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos .(includes ambiguous structures) 0 0 0.0 0.cooo 0 Non-Aebesto.e 0 0 0 0 0 0.0 O.COOO N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (Aid Structures) 0 c 0.0 0 . oooo N/A The estimated uncertainty of this analysis is 1 standard deviation.

Ncn-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003273875

NYC-WTC_000329863

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000329863Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →