NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗TEM asbestos analysis results, PS 130M building-wide.
NYC-WTC_000329853OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Environmental, Inc. 104 East 25th Street New York, New York 10010
N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/19/01
ASBESTOS FIBER ANALYSIS 3Y TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987
Sample Identification Ana2i:sis j;ar^mcters
Project/Site; P.S. ISOM, 143 Baxter St., NY, WY TEM Sample No. / 5726 £1666 Throughout the School Building Date Received: 10/16/01 Grid Openings Analyzed;__ 4
Project Sample No.; Average Grid Opening: 106.00 um
Air Volume: 1699 liters Total Area Analyzed: 0.0450 mmG
Filter Type: MCE 25 mm dlam., Pore Size: C.45 urn Analytica1 Sensitivity: 22.2 s/mm2 Effective Area :3e 5 njm2 0.0045 s/cc
FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc ncrm/m3
Chrysotile Asbestos 0 0 0 0 0 C.0 0.0000 0
Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0
Ambiguous 0 0 0 0 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Kon-Asbestos 0 0 0 0 0 0 0.0 0.oooo N/A No Identification 0 0 0 0 0 0 0.J 0.oooo N/A
Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.
Non-asbestes fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected
The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.
Analyzed by: Report Reviewed by.
Michael A. Gorycki, Ph.D. Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_21MC100_003273861
NYC-WTC_000329853
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329872
TEM asbestos analysis; SAED/EDS; 10/18/01.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329871
TEM asbestos analysis; SAED/EDS; PS 110M project/site; 10/18/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
8 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262780
TEM asbestos analysis for PS 234M; SAED/EDS identification, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411526
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262767
TEM asbestos fiber analysis at PS 234M, includes SAED/EDS methods, Oct 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329855
TEM asbestos analysis data for PS 130M school building.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411527
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329849
TEM asbestos analysis at PS 130M, school building sampling.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000411522
TEM analysis with SAED/EDS for PS 234M, Oct 2, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329872
TEM asbestos analysis; SAED/EDS; 10/18/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329871
TEM asbestos analysis; SAED/EDS; PS 110M project/site; 10/18/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000262780
TEM asbestos analysis for PS 234M; SAED/EDS identification, Oct 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000202620
Laboratory TEM analysis of air samples collected at PS 13QM to detect asbestos fibers using EPA methods.
Similar indexed content
NYC-WTC_000324339
TEM analysis with SAED/EDS for PS 234M, Oct 2001.
Similar indexed content
NYC-WTC_000329872
TEM asbestos analysis; SAED/EDS; 10/18/01.
Similar indexed content
NYC-WTC_000329871
TEM asbestos analysis; SAED/EDS; PS 110M project/site; 10/18/01.
Similar indexed content
NYC-WTC_000329863
TEM asbestos fiber analysis performed across the school building on 10/16/01 for P.S. 130M.
Similar indexed content