104 East 25th St.. 10th Floor New York, New York 40010 www.atc-enviro.com )/ 212.353.8280 Fax 2121353:8306 AS so C I A T E S INC .

November 25, 2002 ■

Mt. Bernard P. Orlan Director, Environmental Health & Safety New York City Department of Education 28-11 Queens Plaza North Long Island City, NY 11101-4008 o/ :

Re: Wipe Samples for Dioxins P. S. 1 (Manhattan) ATC Project No. 15-19125-0340

Dear Mr. Orlan:

ATC Associates InC . (ATC) is pleased to provide this report of the results of the wipe-samples for polychlorinated dibenzo-p-dioxins (PCDDs)and dibenzbfurans (PCDFs) collected on August 27, 2002, at the referenced location. The New York City Department of Education (DOE) i requested these samples to evaluate possible contamination in the school building.

Scope of Work

The samples were collected using gauze pads and hexane as a solvent. The solvent was provided and samples were analyzed by Pace Analytical Services, Inc. (Pace) of Minneapolis, MN, a laboratory experienced in dioxin analysis. The analysis was performed by modified EPA Method 829G using combined capillary column gas chromatography/high resolution mass spectrometry.: <

Wagdi Abdelshabid, Industrial Hygienist of ATC’s New York City office, collected the samples .. consistent with generally accepted industrial hygiene practices. There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The results of the sampling represent conditions found on the date the samples were collected.

Results

ATC submitted three wipe samples for PCDDs/PCDFs to Pace for analysis. Samples were taken from representative floor areas throughout the building. The sample area for each sample was one square meter (1 m2). The areas sampled were:

• rWThlx»bbyLi> ; • Hallway by Room 215; • Hallway by Room 403.

i-''

CITY_2IMC10 0_0 0 3 2 7313F

NYC-WTC_000329347

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000329347Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Dioxin wipe sample report, P.S. IM, Nov 2002

NYC-WTC_000196715

Report detailing results of wipe samples collected to evaluate polychlorinated dibenzo-p-dioxins and dibenzofurans contamination at a school.

Similar indexed content

Compare copies and versions →