NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan November 25, 2002
Wipe Samples for Dioxins ■ 4 4 Page? ,
P. S. 1 (Manhattan) ATC Project No. 15-19125-0340
Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer
were then converted to 2, 3. 7, 8 tetrachloro-dibenzb-p-dioxin (2, 3, 7, 8-TGDD) equivalents by
multiplying by an established equivalency factor. This provides a single value (in nanograms)
for the analytical results for each sample. A copy of the laboratoiy analysis report is attached.
The results are shown in the following table. ) / ■ 7
1)1 OXIN WIPE SAMPLE RE STETS ■ 4 ,<4' 4^) 4'-
2,3,7,8 TCDD EQUIVALENTS - Nanograms per square meter (ng/m^)
■ August 27,12002 ' '
JN
_________ _______
■
Main Lobby Z DXl 0.000083
Hallway by Room 215 /DX2 0.00018
J /'
Hallway by Room 403 / DX3 0.000045
The New York State Department of Health (NYSDOH) established guidelines for dioxin for the
re-occupancy of the Binghamton State Office Building following a PCB fire. The NYSDOH
I
guideline for dioxin on surfaces is 25 nanograms per square meter (25 ng/m^).
The concentrations on indoor surfaces ranged from 0.000045 to 0.00018 nanograms per square
meter (ng/m2). The levels found in all of these samples are below the NYSDOH guideline of
25 ng/m2. /■ ■
It is not possible to determine when the 2, 3, 7, 8 - TCDD equivalents detected in these samples
was deposited. Dioxin samples were not collected from these locations prior to these samples
i -r therefore a background samplers not available for comparison purposes.
t.' It is our pleasure to provide these indoor environmental services to the NYC Department of
Education. If you have any questions about this report, please call (212) 353-8280, extension
14212. .
Sincerely,'
ATC Associates,Inc.
[ I.
I
James R. Cohn, CIH, CSP
Regional Manager
Industrial Hygiene Division
Attachment
lA b
Ibi'-