Pace Analytical Services, inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
’ /
we Analytical_________ Method 8290 Analysis Results
Te!: 612-607-1700
Fax' 612- 607-6444
Client - ATC ASSOCIATES
Client's Sample ID ATC-0906-STY-DX-3
Lab Sample ID 103841391
Filename U21016A_14
injected By MRO
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Colieeted 09/06/2002
ICAL Date 08/06/2002 Received 09/10/2002
CCal Filename{s) U21016A 02 & U21016A_15 Extracted 10/06/2002
Method Blank ID BLANK-2262 Analyzed 10/16/2002 20:20
Native Cone EMPC LRL Internal ng's Percent
isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2.3,7,8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 73
Total TCDF ND 0.00200 2.3,7,8-TCDD-13C 2.00 77
1,2,3,7,8-PeCDF-13C 2.00 85
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 89
Total TCDD 0.0020 0.00200 J 1,2,3,7,8-PeCDD-13C 2.00 87
1,2.3,4,7,8-HxCDF-13C 2.00 97
1,2.3,7,8-PeCDF ND 0.01000 1,2,3.6,7,8-HxCDF-13C 2.00 113
2,3,4,7.8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 106
Total PeCDF ND 0.01000 1,2.3,7,8.9-HxCDF-13C 2.00 107
1,2,3,4,7.8-HxCDD-13C 2.00 104
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 106
Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 115
1,2,3,4,7,8,9-HpCDF-13C 2.00 107
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 110
1.2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 92
2,3,4,6,7,8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 73
1,2,3,6,7.8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.000040 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD 0.0400 0.02000 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis ’ = See Discussion
Report No.... 1062385
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003273054
NYC-WTC_000329246