NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
TM
we Analytical__________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax- 612- 607-6444
Client - ATC ASSOCIATES
Client's Sample ID ATC-0827-1M-DX1
Lab Sample ID 103815254
Filename 'U21010B_13
Injected By MRO
Total Amount Extracted 1.00 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 08/27/2002
ICAL Date 08/06/2002 Received 08/28/2002
CCal Filename(s) U21010A_14 & U21010B_16 Extracted 09/29/2002
Method Blank ID BLANK-2231 Analyzed 10/11/2002 05:30
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2.3.7.8-TCDF ND 0.00230 A 2,3,7,8-TCDF-13C 2.00 79
ri Total TCDF 0.0076 0.00200 J 2,3.7,8-TCDD-13C
1.2.3,7,8-PeCDF-13C
2.00
2.00
75
85
2.3.7.8-TCDD ND 0.00310 A 2,3,4,7,8-PeCDF-13C 2.00 87
Total TCDD 0.0170 0.00200 1,2,3,7,8-PeCDD-13C 2.00 82
1,2,3,4,7,8-HXCDF-13C 2.00 86
1,2.3,7.8-PeCDF ND 0.01000 1.2,3,6,7,8-HxCDF-13C 2.00 98
2.3,4.7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 92
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 93
1,2,3,4,7,8-HxCDD-13C 2.00 96
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00- 92
Total PeCDD ND 0.01000 . 1,2,3,4,6,7,8-HpCDF-13C 2.00 90
1,2,3,4,7,8,9-HpCDF-13C 2.00 84
1,2.3,4,7.8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 84
1,2,3.6,7,8’HxCDF ND 0.01000 OCDD-13C 4.00 63
2.3,4.6.7.8-HxCDF ND 0.01000
1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3.4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8.9-HxCDD-13C 2.00 NA
1.2,3,4,7.8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 79
1,2,3,6,7,8-HxCDD ND 0.01000
1,2,3,7.8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.000083 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1
1,2,3,4,6.7,8-HpCDD ND 0.01000
( Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD 0.0830 0.02000 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,B-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on sigrial-to-noise measurement S = Saturated signal
J = Concentration detected is below'the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 1061946
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_003042427
NYC-WTC_000309597
OCR can misread numbers and units. Confirm readings against the page image before using them.