Mr. Bernard P. Orlan August 28,2002 Indoor Air Quality Assessment Page 4 J.H.SJ31M ATC Project No. 15-19125-0346
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TVOC Concentration
The TVOCs indoor concentrations ranged from 0.1 to 0.2 ppm. These concentrations were below the AIHA guideline for odor control of 1 ppm. The outdoor TVOC concentration was 0 ppm.
OBSERVATIONS
During this assessment, ATC noted the following: • The interior of the building appeared clean and free of dust and debris; • The building was not occupied at the time of the assessment; • No smoke odor was detected in the building;
FINDINGS Based on the real-time measurements, the following findings are presented:
1. Concentrations of CO and TVOCs were within applicable standards and guidelines. 2. Forty (40) of the indoor measurements were above the range of 73 to79 °F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the summer season. 3. All of the indoor measurements for relative humidity were within the ASHRAE- recommended range of 30 to 60 percent for occupant comfort. 4. Two (2) of the indoor measurements for CO2 were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The highest reading was measured in the basement office with 9 occupants at 2:46 PM. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration. 5. Two (2) of the indoor measurements for PM2.5 were above the NPAAQS of 65 pg/m^ 24- hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Eight (8) of the forty-seven (47) instantaneous indoor readings were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children. All of the outdoor measurements for PM2.5 were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children.
CITY_21MC100_003272312
NYC-WTC_000328525
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000316199
ATC report of IAQ measurements at the referenced NYC DOE school, August 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199261
ATC Associates reports indoor air quality measurements collected at J.H.S. 131M on August 22, 2002 to verify acceptable air quality.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000316216
ATC report of indoor air quality measurements at PS 131M, August 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317091
IAQ memo documenting measurements at DeSoto School (PS 130M) in Aug 2002.
12 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000328765
Indoor air quality measurements at DeSoto School PS 130M.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000316188
DOE requested IAQ measurements at J.H.S. 131M; report issued August 2002.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309455
ATC report on indoor air quality measurements at Alfred E. [name] (P.S. IM), Aug 2002.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317101
IAQ memo for DeSoto School measurements conducted Aug 2002.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350024
Memo/letter from ATC regarding DOE project PS IM at 28-11 [name], Aug 2002.
11 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309465
ATC IAQ measurements report for Alfred E. [name] (P.S. IM), Aug 2002.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397276
IAQ measurements report for PS 234M; April 12, 2002.
10 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371828
ATC indoor air quality report for PS 234M; measurements collected in April 2002.
10 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000239434
Report on indoor air quality measurements conducted at a New York City high school on August 22, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239510
Report from ATC Associates documenting indoor air quality measurements conducted at a school in August 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238685
Report providing indoor air quality measurements collected at a New York City Department of Education school to verify acceptable air levels.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238877
Letter and report on indoor air quality measurements collected at P.S. 130M to verify acceptable air quality levels.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199261
ATC Associates reports indoor air quality measurements collected at J.H.S. 131M on August 22, 2002 to verify acceptable air quality.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317091
IAQ memo documenting measurements at DeSoto School (PS 130M) in Aug 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000316199
ATC report of IAQ measurements at the referenced NYC DOE school, August 2002.
Similar indexed content
NYC-WTC_000199261
ATC Associates reports indoor air quality measurements collected at J.H.S. 131M on August 22, 2002 to verify acceptable air quality.
Similar indexed content
NYC-WTC_000316216
ATC report of indoor air quality measurements at PS 131M, August 2002.
Similar indexed content
NYC-WTC_000317091
IAQ memo documenting measurements at DeSoto School (PS 130M) in Aug 2002.
Similar indexed content
NYC-WTC_000328765
Indoor air quality measurements at DeSoto School PS 130M.
Similar indexed content