NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

PACE Analytical, ATC sample 103302774

Machine-extracted title · confidence 28%

PACE report metadata for ATC sample 103302774; wipe matrix.

NYC-WTC_000326624–000326627
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

FEB-22-02 .10:45 FROM-PACE.ANALYTICAL 612-BD/-6444 T-63T P.D2/DE F-07S 1700 Elm Street - Suite 200 Minneapolis, MN 55414

/\^ceAnalytical'' Tel: S12’607-1700 Fay fit ?- 607.^444 / Method 8290 Analysis Results Client-ATC Client's Sample ID ATC-0131-89M-DX1 Lab Sample ID 103302774 Filename F20219B_10 injected By BAL Total Amount Extracted 1 m2 Matrix WIPE % Moisture NA Dilution NA Dry Weight Extracted NA Collected 01/31/2002 ICALDate □1/24/2002 Received 02/04/2002 CCal Filename(s} F202196^01 & F20219B_16 Extracted 02/15/2002 Method Blank ID BLANK-1468 Analyzed 02/20/2002 03:30 Native Cone EMPC LRL Internal ng's Percent Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery 2,3,7,S-TCDF 0.0022 0.00200 E. 2.3,7,S-TCDF-1SC 2.00 70 Total TCDF 0,021 0.O0200 2,3,7,3-TCDD-13C 2,00 70 1,2,3,7,8-PeCDF-13C 2.00 75 2,3,7,8-TCDD ND 0,00200 2,3.4,7.8-PeCDF-15C 2.00 70 Total TCDD 0.090 0,00200 1.2,3,7,8-PeCDD-13C 2.00 66 1,2,3.4,7, B-HxCDF-ISC 2.00 108 1.2,3,7,8-PeCDF ND 0.01000 1,2.3,6,7,8-HxCDF-13C 2.00 50 2,3,4,7,S-PeCDF ND 0.01000 2,3,4,6,7,a-HxCDF-13C 2.00 76 Total PeCDF ND 0.01000 1,2,3,7,S,9-HxCDF-13C 2.00 89 1,2,3,4,7,8-HxCDD-13C 2.00 114 1,2,3,7,8-PeCDD ND - 0.01000 1.2,3,6,7,8-HxCDD-13C 2.00 80 Total PeCDD 0.030 - 0.01000 1,2,3,4,6.7,8-HpCDF-13C 2.00 79 1.2,3,4,7,8,9-HpCDF-13C 2.00 70 1,2,3,47.8-HxCDF ND 0.01000 1,2,3,4.6,7,8-HpCDD-13C 2.00 77 1,2.3,6.7,8-HxCDF ND 0.01000 OCDD-13C 4,00 64 2,3,4,6,7,8-HxCDF ND 0.01000 1,2,3.7,8,9-HxCDF ND 0.01000 1,2.3,4-TCDD-13C 2.00 NA Total HxCDF ND 0.01000 1,2,3.7,8,9-HxCDD-l3C 2.00 NA

1,2,3,4,7.8-HxCDD •ND 0.01000 2,3,7,8-TCDD-37C14 0.20 69 1,2,3,6,7,8-HxCDD ND 0.01000 1,2,3,7.8,9-HxCDD ND 0,01000 Total HxCDD 0.044 0.01000 J’’

1,2,3,4,6,7,8-HpCDF ND 0.01000 L Total 2,3,7,8-TGDD 1.2,S,4,7,S,9-HpCDF ND 0,01000 "'Equivalence: 0.000055 ng/m2 Total HpCDF ND 0.01000 (lJsirTg-1TE..Eaetprs)

1,2,3,4,6,7,8-HpCDD ND 0.01000 Total HpCDD ND 0.01000

OCDF ND 0.02000 OCDD 0.055 0.02000 BJ LRL = Lower Reporting Limit Cone = Concontraiion (Totals include 2,3,7,8-substitUTed isomers) I = Interference EM PC = Estimated Maximum Possible Concentration E - PCDE interference A= Detection Limit based on slgnal-to-noise measurement S = Saturated signal J = Concentration detected is below the calibration range ND = Not Detected B = Less than 10 times higher than method blank level NA = Not Applicable P - Recovery outside of target range NC = Not Calculated Nn = Value obtained from additional analysis * = See Discussion Report No.... 02-1053715

REPORT OF LABORATORY ANALYSIS This report shall not ba reproduoed, except in full, without ths written consent of Pace Analytical Services, Inc.

CITY_21MC100_005390240

NYC-WTC_000326624

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000326624Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →