NYC 9/11 Public Portal Document
FEB-28-02 08:22 FROM-PACE ANALYTICAL E12-B07-E444 T-7B0 P.04/0B F-33E
1700 Eirn Street - Suite 200
Minneapolis, MN 55414
^ceAnalytical__________ Tel: 612-607-1700
Fax' 612- 607-6444
Method 8290 Analysis Results
Client - ATC
Client's Sample ID ATC-0205-234M-DX1
Lab Sample ID 103307195 , 1-
Filename F20222A_04
Injected By MASB
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 02/05/2002
ICAL Date 01/24/2002 Received 02/06/2002
CCal Filename(s) F2O222A_O1 &F20222A_14 Extracted 02/18/2002
Method Blank ID BLANK-1471 Analyzed 02/22/2002 10:45
Native Cone EMPC LRL internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0031 0.0020 J 2,3,7,8-TCDF-13C 2.00 62
Total TCDF 0,0410 0.0020 2,3.7,8-TCDD-13C 2.00 60
1,2,3,7.8-PeCDF-13C 2,00 79
2,3,7,8-TCDD ND 0-0020 2,3,4.7,8-PeCDF-13C 2.00 7S
Total TCDD 0.0820 0.0020 1,2,3,7,8-PeCDD-13C 2.00 78
1,2,3,4,7,8-HxCDF-13C 2,00 82
1,2,3,7,8-PeCDF ND 0.0100 1.2,3,6,7.8-HxCDF-13C 2,00 78
2.3,4.7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 73
Total PeCDF 0.0530 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 67
1,2,3,4,7,8-HxCDD-13C 2.00 77
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 70
Total PeCDD 0.0250 0.0100 J 1,2.3,4,6,7.8-HpCDF-13C 2.00 69
1,2,3,4,7,8,9-HpCDF-13C 2.00 65
1,2.3,4,7,8-HxCDF ND 0.0100 1,2,3.4,6,7.8-HpCDD-13C 2.00 76
1.2,3,6.7,8-HxCDF ND 0.0100 OCDD-13C 4.00 46
2,3,4,6,7,8-HxCDF 0.022 0.0100 E
1,2,3,7,8.9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 0.0380 0.0100 J 1.2,3.7,8.9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 67
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,S,9-HxCDD ND 0.0100
Total HxCDD 0.3700 0.0100
1,2,3,4,6,7,8-HpCDF 0,0240 0.0100 J Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0,0010 ng/m2
Total HpCDF 0,0240 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0380 0.0100 J
Total HpCDD 0.0980 0.0100
OCDF ND 0.0200
OCDD 0.1100 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals Include 2,3,7,8-substituted isomers) I interference
EMPC = estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND 3 Not Detected
B !s Less than 1O times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1053790
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Paos Analytical Services. Inc.
CITY_21MC100_003057386
NYC-WTC_000308992