Method 8290 Analysis Results
.1
Client-ATC
Client's Sample ID ATC-1220-89M-DX9
Lab Sample ID 103233979
Filename F20103A_11
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 12/20/2001
ICALDate 01/02/2002 Received 12/21/2001
CCal Filename(s) F20102A„22 & F20103B_01 Extracted 12/23/2001
Method Blank ID BLANK-1389 Analyzed 01/03/2002 16:25
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3.7,8-TCDF 0.0096 0.0020 J 2,3,7,8-TCDF-13C 2.00 75
Total TCDF 0.4800 0.0020 2,3,7,8-TCDD.-13C.'. 2.00 79
J 1,2,3.7,8-PeCDF-13C 2.00 73
2,3,7,8-TCDD 0.0026 0.0020 J 2,3,4,7.8-PeCDF-13C 2.00 .. 59
Total TCDD 0.6200 0.0020 1,2,3,7,8-PeCDD-13C 2.00 ■ 74
I 1,2,3,7,8-PeCDF ND 0.0100
1,2,3,4,7,8-HxCDF-13C
1,2,3,6,7,8-HxCDF-13C
2.00
2.00
124
77
2,3,4,7,8-PeCDF 0.0150 0.0100 J 2,3,4.6,7,8-HxCDF-13C 2.00 90
Total PeCDF 0.1700 0.0100 1,2,3.7,8,9-HxCDF-13C 2.00 106
1,2,3.4,7,8-HxCDD-13C 2.00 125
1,2,3.7,8-PeCDD 0.0120 0.0100 J ' 1,2.3.6,7,8-HxCDD-13C 2.00 80
Total PeCDD 0.3800 0.0100 1,2,3,4,6.7,8-HpGDF-13C 2.00 102
1,2,3,4,7,8,9-HpCDF-13C 2.00 114
1,2,3,4,7.8-HxCDF 0.0160 0.0100 J 1,2,3.4,6,7,8-HpCDD-13C 2.00 114
1,2,3,6,7,8-HxCDF 0.0170 0.0100 J OCDD-13C 4.00 116.
2,3.4,6,7.8-HxCDF 0.0220 0.0100 J
1,2,3,7.8.9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
il. Total HxCDF 0.1700 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD 0.0130 0.0100 J 2,3,7.8-TCDD-37CI4 0.20 85
a 1,2,3,6,7,8-HxCDD
1,2,3,7,8,9-HxCDD
0.0190
0.0110 .
0.0100 J
0.0100 J
Total HxGDD 0.5700 0.0100
1,2,3,4.6.7,8-HpCDF. ■ 0.0780 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.032 ng/m2
J Total HpGDF 0.1100 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.2100 0.0100
(i Total HpCDD 0.4300 0.0100
OCDF 0.1200 0.0200
OCDD 1.6000 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) 1 = Interference
EMPC = Estimated Maximum Possible Concentration ■ E = PCDE Interference
A = Detection Limit based on signal-to-noiss measursment S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis • = See Discussion
Report No.... 01-1052540
REPORT OF LABORATORY ANALYSIS
This report shall not bs reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_012156690