NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street • Suite 200
Minneapolis, MN 55414
TW
Analytical Tel: 612-607-1700
Fax' 612- 607-6444
Method 8290 Blank Analysis Results
Client - ATC
I
Lab Sample ID BLANK-1592 Matrix WIPE
Filename F20429A_04 Dilution NA
Total Amount Extracted 1 m2 Extracted 04/24/2002
ICAL Date 04/12/2002 Analyzed 04/29/2002 12;41
CCal Filename(s) F20429A_01 & F20429A_15 Injected By BAL
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7.8-TCDF ND — 0.00200 2,3,7,8-TCDF-13C 2.00 75
Total TCDF ND -- 0.00200 2,3,7,8-TCDD-13C 2.00 78
1,2,3,7,8-PeCDF-13C 2.00 87
2,3,7,8-TCDD ND 0.00200 2,3,4,7.8-PeCDF-13C 2.00 81
Total TCDD 0.051 0.00200 1,2,3,7,8-PeCDD-13C 2.00 87
1,2,3,4,7,8-HxCDF-13C 2.00 97
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 81
2,3,4.7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 83
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 84
1,2,3,4,7,8-HxCDD-13C 2.00 97
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 89
Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 87
1,2,3,4,7,8,9-HpCDF-13C 2.00 81
1,2,3,4,7,8-HxCDF ND 0.01000 1,2.3,4,6,7,8-HpCDD-13C 2.00 98
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 68
2,3,4,6,7,8-HxCDF ND 0.01000
•i NA
1.2,3.7,8,9-HxCDF ND 0.01000 1,2,3.4-TCDD-13C 2.00
Total HxCDF ND 0.01000 1,2.3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37Cl4 0.20 87
1,2,3.6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD ND 0.01000
1,2,3,4,S,7,8-HpCDF ND 0.01000 Total 2,3,7.8-TCDD
1,2.3.4.7,8,9-HpCDF ND 0.01000 Equivalence: 0.00 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1.2,3,4.6,7.8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD ND 0.02000
Cone 3 Concentration (Totals include 2,3,7,8-substituted isomers). I = Interference
EMPC > Estimated Maximum Possible Concentration E = PCDE Interference
LRL 3 Lower Reporting Limit ND 3 Not Detected
J 2! Concentration detected is below ths calibration range NA = Not Applicable
P s Recovery outside of target range NC 3 Not Calculated
A 3 Detection Limit based on signal-to-noise measurement * 3 See Discussion
Report No.... 02-1056374
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_002900566
NYC-WTC_000404693
OCR can misread numbers and units. Confirm readings against the page image before using them.