NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
tm
^ace Analytical_________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client's Sample ID ATC-0413-M833-DX1
Lab Sample ID 103468278
Filename F20429A_12
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/13/2002
ICAL Date 04/12/2002 Received 04/16/2002
CCal Filename(s) F20429A_01 & F20429A_15 Extracted 04/24/2002
Method Blank ID BLANK-1592 Analyzed 04/29/2002 19:14
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF 0.0031 0.00200 J 2,3,7,8-TCDF-13C 2.00 66
Total TCDF 0.1100 0.00200 2.3,7,8-TCDD-13C 2.00 71
1,2,3,7,8-PeCDF-13C 2.00 77
2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 71
Total TCDD 0.2800 0.00200 B 1,2,3,7,8-PeCDD-13C 2.00 80
1,2,3.4,7,8-HxCDF-13C 2.00 88
1,2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 69
2,3,4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 74
Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 70
1,2,3,4,7,8-HxCDD-13C 2.00 96
1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 82
Total PeCDD 0.0650 0.01000 1,2,3,4.6,7,8-HpCDF-13C 2.00 75
1,2,3,4,7,8,9-HpCDF-13C 2.00 65
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 86
1,2,3,6,7,8-HxCDF ND 0.01000 OCDD-13C 4.00 58
2,3,4,6,7,8-HxCDF ND 0.01000
( 1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 80
1,2.3,6,7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
TotJtl HxCDD 0.0230 0.01000 J
1,2,3,4,6,7.8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD
1,2,3,4.7.8,9-HpCDF ND 0.01000 Equivalence: 0.00056 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1.2.3,4.6.7,8-HpCDD 0.0140 0.01000 J
Total HpCDD 0.0250 0.01000 J
OCDF ND 0.02000
OCDD 0.1100 0.02000
LRL = Lower Reporting Limit
Cone s Concentration (Totals include 2,3,7,S-substttuted isomers) I = Interference
EMPC ■ Estimatefl Maximum Possible Concentration E = PCDE Interference
A « Detection Limit based on signal-to-noise measurement S = Saturated signal
J « Concentration detected is below the calibration range ND - Not Detected
B s Less than 10 times higher than method blank level NA = Not Applicable
P » Recovery outside of target range NC = Not Calculated
Nn s Value obtained from additional analysis ’ = See Discussion
Report No.... 02-1056374
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Sendees, Inc.
CITY_21MC100_002900567
NYC-WTC_000404694
OCR can misread numbers and units. Confirm readings against the page image before using them.