NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
^ace Analytical_______ _ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-5'144
Client-ATC
Client's Sample ID ATC-0308-89M-DX2
Lab Sample ID 103384764
Filename U20326B_11
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/08/2002
ICAL Date 03/25/2002 Received 03/12/2002
CGal Filename(s) U20326B_02 & U20326B_17 Extracted 03/21/2002
Method Blank ID BLANK-1528 Analyzed 03/27/2002 00:15
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/rn2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF —- 0.0023 0.0020 I 2,3,7,8-TGDF-13C 2.00 70
Total TCDF 0.053 0.0020- 2,3,7,8-TCDD-13C 2.00 68
1,2,3,7,8-PeCDF-13C 2.00 68
2,3,7,8-TCDD ND 0.0034 A 2,3,4,7,8-PeCDF-13C 2.00 67
Total TCDD 0.017 0.0020 1,2,3,7,8-PeCDD-13C 2.00 67
1,2,3,4,7,8-HxCDF-13C 2.00 98
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 81
2.3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 83
Total PeCDF 0.011 0.0100 J 1,2,3,7,8,9-HxCDF-13C 2.00 82
1,2,3,4,7,8-HxCDD-13C 2.00 119
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 70
Total PeCDD ND 0.0100 1.2,3,4,6,7,8-HpCDF-13C 2.00 85
T,2,3,4,7,8,9-HpCDF-13C 2.00 74
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 79
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 70
2,3.4,6,7.8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 78
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3,4,5,7,8-HpCDF 0.014 O.OTOO J Total 2,3,7,8-TGDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00043 ng/m2
Total HpCDF 0.014 0.0100 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 0.0220 0.0100 I
Total HpCDD 0.018 0.0100 J
OCDF 0.023 0.0200 J
OCDD 0.270 0.0200
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) I = Interference
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement - . S = Saturated signal .
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1055016
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC100_005390313
NYC-WTC_000326671