Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
’^ace Analytical______ ___ Method 8290 Analysis Results
Tel: 612-607-1700
Fax' 612- 607-6444
/
Client-ATC
Client's Sample ID ATC-0308-89M-DX3
Lab Sample ID 103384772
Filename U203263 12
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 03/08/2002
ICAL Dale 03/25/2002 Received 03/12/2002
CCal Filename(s) U20326B_02 & U20326B_17 Extracted 03/21/2002
Method Blank ID BLANK-1528 Analyzed 03/27/2002 01:04
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.0031 A 2,3,7,8-TCDF-13C 2.00 70
Total TCDF ND 0.0020 2,3,7,8-TCDD-13C 2.00 70
1,2,3,7,8-PeCDF-13C 2.00 75
2,3,7,8-TCDD ND 0.0026 A 2,3,4,7,8-PeCDF-13C 2.00 73
Total TCDD 0.0071 0.0020 J 1,2,3,7,8-PeCDD-T3C 2.00 74
T,2,3,4,7,8-HxCDF-13C 2.00 107
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 85
2,3,4,7,8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 91
Total PeCDF ND 0.0100 1,2,3,7,8,9-HxCDF-13C 2.00 84
1.2,3,4,7,8-HxCDD-13C 2.00 120
1,2,3,7,8-PeCDD ND 0.0100 1,2,3,6,7,8-HxCDD-13C 2.00 79
Total PeCDD ND 0.0100 1,2,3,4,6,7,8-HpCDF-13C 2.00 94
1,2,3,4,7,8,9-HpCDF-13C 2.00 79
1,2.3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 87
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C 4.00 66
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3.7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37Cl4 0.20 79
1,2,3,6,7,8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1,2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3,7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.00 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.057 0.0200 I
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3 7 8-substituted isomers) 1 = Interference
EWPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA - Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1055016
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in. full,
without the written consent of Pace Analytical Services, Inc.